Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05OT00751
Permit Details
Apply Date:
04/01/2005
Applicant:
DARCY GERARD
Description:
FLOODPLAIN USE PERMIT
Permit Reviews
Permit Number - T05OT00751
Permit Status: Final
Permit Description: FLOODPLAIN USE PERMIT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/01/2005 | FLOODPLAIN | 05/04/2005 | COMPLETED |
05/27/2005 | RESUBMITTAL | 06/14/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05OT00751
Permit Status: Final
Permit Description: FLOODPLAIN USE PERMIT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/27/2005 | 27 May 2005 FLOODPLAIN USE PERMIT # T05OT0343 PROJECT ADDRESS: 415 N. Court Ave. PARCEL # 117-10-1550 PROPERTY OWNER'S NAME: Todd Mazur The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as, MEYER AVENUE & COURT AVENUE LOT 3 for the purpose of constructing a new structure (Single Family Residence). The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Management Regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Management Regulations will require a new application, submittal, and issuance of an additional Floodplain Use Permit. The following conditions apply to this permit (Tucson Code, Section 26): 1) The lowest floor elevation of the new structure, all electrical equipment, and any machinery and associated equipment serving the structure shall be placed upon a dirt, concrete, or similar type solid pad to a minimum elevation of 2360.5' above sea level, National Geodetic Vertical Datum (NGVD) 1929, in accordance with the Drainage Report prepared by CMG Drainage Engineering, Inc. signed/sealed on 16 January 2002. Certification of the lowest floor elevation of the structure and all applicable machinery and equipment (furnaces, hot water heaters, heat pumps, air conditioners and their associated equipment - including all electrical equipment on an open utility platform that provide utility services for the building), shall be performed by a state-registered land surveyor on an elevation certificate. The elevation certificate must be fully completed, signed and certified upon completion of construction of the structure and all associated machinery and equipment, as discussed above. The completed elevation certificate must be returned to Engineering Division, Development Services Department, at the City/County Public Works building - 201 N. Stone Ave., 1st floor - ATTN: Beverley Hester, P.E. A hold will be placed on the certificate of occupancy until a properly completed elevation certificate is returned to this office. 2) All work shall conform to the approved site plan (Development Services Department - DSD - permit activity #T04CM05457), and the conditions specified under this Floodplain Use Permit (DSD # T05OT00751), which are made a part of this permit. 3) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. Existing drainage patterns at the property lines shall not be obstructed in any fashion, other than as may be shown on the approved site plan and/or described in the Drainage Report. 4) Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T05OT00751. FOR INFORMATION PLEASE CALL 791-5550." 5) A right-of-way permit is required for any development, excavation, or construction activity within the public Right of Way. Contact Tucson Department of Transportation - Permits and Codes Section, Engineering Division at 791-5100 for questions relating to such permit information. 6) This permit becomes invalid and is subject to an additional floodplain permit application and review, if any proposed or required modifications change the location or configuration of the structure and/or site development. 7) Any walls to be proposed will require a separate floodplain use permit application, review and approval prior to construction. Please call Development Services Department at 791-5550 for questions. This Floodplain Use Permit will be automatically revoked and becomes invalid, if development onsite results in non-compliance with conditions set forth in this permit. A hold will be placed on the certificate of occupancy until a properly completed certificate is returned to this office. APPLICANT: Gerard Darcy / DESA ADDRESS: 1202 E Broadway Blvd., Ste. 112 Tucson AZ 85719 PHONE: (520) 624-9366 The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |