Permit: T05CM06396
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
2807 N CORTE MELODIA
Address NEW:
2807 N CORTE MELODIA
Apply Date:
12/22/2005
Applicant:
PRIMAVISTA HOMES INC ,
Description:
SFR:TD#16-20-82
Contractors:
- PRIMAVISTA HOMES INC ,
Permit Reviews
Permit Number - T05CM06396
Permit Status: C of o
Permit Description: SFR:TD#16-20-82
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/22/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 12/22/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM06396
Permit Status: C of o
Permit Description: SFR:TD#16-20-82
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/22/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM06396
Permit Description: SFR:TD#16-20-82
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2005 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | IVRS - Inspection :* 1) ALL EXTERIOR FOOTINGS OK TO POUR |
| 12/28/2005 | ELECTRIC - UFER | DQUINN | Approved | IVRS - Inspection :* |
| 01/12/2006 | PLUMBING - SEWER HCS CONNECT | DQUINN | Approved | IVRS - Inspection :* |
| 01/12/2006 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | IVRS - Inspection :* |
| 01/17/2006 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |
| 03/01/2006 | ELECTRIC - TEMPORARY SERVICE | WNORTH | Approved | |
| 03/01/2006 | ELECTRIC - CABLE DROP | WNORTH | Approved | |
| 03/02/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 03/10/2006 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 03/15/2006 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |
| 04/11/2006 | PLUMBING - YARD WTR LINE/TEST | WNORTH | Approved | 1) NO PRESSURE |
| 04/11/2006 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 04/11/2006 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
| 04/11/2006 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 04/17/2006 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 04/17/2006 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 05/19/2006 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 05/19/2006 | U VALUE FOR WINDOW | DQUINN | Approved | IVRS - Inspection :* |
| 06/07/2006 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection :* |
| 03/01/2007 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 03/01/2007 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 03/01/2007 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 03/01/2007 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 03/02/2007 | PERMIT FINALED | JWEATHER | Approved |