Permit Number - T05CM05731
Permit Status: Si_xpire
Permit Description: SFR:TD16-33-47
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/14/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/16/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05731
Permit Status: Si_xpire
Permit Description: SFR:TD16-33-47
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
11/14/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
11/14/2005 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
11/14/2005 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Outstanding Inspections
Permit Status: Si_xpire
Permit Number: T05CM05731
Permite Description: SFR:TD16-33-47
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
PERMIT FINALED | N/A | Not Inspected |
Completed Inspections
Permit Status: Si_xpire
Permit Number: T05CM05731
Permit Description: SFR:TD16-33-47
Total Completed Inspections - 29
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2005 | PLUMBING - SEWER HCS CONNECT | HPEDROZA | Approved | IVRS - Inspection :* 1) PARTIAL BWV WILL INSPECT AT FINALS 2) HCS LOT HOOKED UP |
12/20/2005 | PLUMBING - BACK WATER VALVE | HPEDROZA | Approved | IVRS - Inspection :* |
12/20/2005 | PLUMBING - YARD WTR LINE/TEST | HPEDROZA | Approved | IVRS - Inspection :* |
12/20/2005 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection :* |
01/18/2006 | ELECTRIC - UNDERGROUND | CTREVILL | Approved | IVRS - Inspection :* |
01/18/2006 | ELECTRIC - UFER | CTREVILL | Approved | IVRS - Inspection :* |
01/20/2006 | BUILDING PRE-SLAB | HPEDROZA | Approved | IVRS - Inspection :* |
01/20/2006 | STEM WALL/RETAINING WALL | HPEDROZA | Approved | IVRS - Inspection :* |
01/20/2006 | EXCAVATION/LAYOUT REBAR & ZON | HPEDROZA | Approved | IVRS - Inspection :* |
02/22/2006 | EXT METAL CLIPS/EXT SHEATHING | CTREVILL | Approved | |
02/22/2006 | ROOF NAILING | CTREVILL | Approved | IVRS - Inspection :* |
03/15/2006 | MECHANICAL - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
03/15/2006 | U VALUE FOR WINDOW | CTREVILL | Approved | IVRS - Inspection :* |
03/15/2006 | STUCCO MESH | CTREVILL | Approved | IVRS - Inspection :* |
03/16/2006 | ELECTRIC - TEMPORARY SERVICE | WNORTH | Approved | |
03/16/2006 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
03/16/2006 | ELECTRIC - CABLE DROP | WNORTH | Approved | IVRS - Inspection :* |
03/17/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER W. NORTH |
03/20/2006 | ELECTRIC - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
03/20/2006 | FRAMING | CTREVILL | Approved | IVRS - Inspection :* |
03/31/2006 | SHEET ROCK NAILING | CTREVILL | Approved | IVRS - Inspection :* |
05/15/2006 | MECHANICAL - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
05/15/2006 | PLUMBING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
05/15/2006 | PLUMBING - GAS PRESSURE TEST | CTREVILL | Approved | IVRS - Inspection :* |
05/15/2006 | OUTDOOR LIGHTING FINAL | CTREVILL | Approved | IVRS - Inspection :* |
05/15/2006 | ELECTRIC - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
05/17/2006 | BUILDING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
05/19/2006 | SITE - SEWER | CTREVILL | Approved | |
05/19/2006 | PLUMBING - GAS PRESS TEST FNL | CTREVILL | Approved |