Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address NEW:
6602 E SPLENDID LN
Apply Date:
10/31/2005
Applicant:
U S HOME OF ARIZONA *P *C
Description:
SFR TD# 16-36-93
Contractors:
  • U S HOME OF ARIZONA *P *C

Permit Reviews

Permit Number - T05CM05523
Permit Status: C of o
Permit Description: SFR TD# 16-36-93
Start Date Submittal Complete Date Status  
10/31/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 11/01/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM05523
Permit Status: C of o
Permit Description: SFR TD# 16-36-93
Total Outstanding Activity Conditions - 1
Date Name
10/31/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM05523
Permit Description: SFR TD# 16-36-93
Total Completed Inspections - 25
Date Description Inspector Results Comments
01/10/2006 PLUMBING - ROUGH, SOIL CTREVILL Approved IVRS - Inspection :*
01/19/2006 PLUMBING - SEWER HCS CONNECT JRIVA Approved IVRS - Inspection :*
01/19/2006 PLUMBING - YARD WTR LINE/TEST JRIVA Approved IVRS - Inspection :*
01/25/2006 ELECTRIC - UNDERGROUND JRIVA Approved IVRS - Inspection :*
01/25/2006 ELECTRIC - UFER JRIVA Approved IVRS - Inspection :*
01/25/2006 BUILDING PRE-SLAB JRIVA Approved IVRS - Inspection :*
01/25/2006 EXCAVATION/LAYOUT REBAR & ZON JRIVA Approved IVRS - Inspection :*
03/09/2006 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
03/09/2006 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*
04/07/2006 ELECTRIC - TEMPORARY SERVICE FSALDIVA Approved IVRS - Inspection :*
04/07/2006 ELECTRIC - CABLE DROP FSALDIVA Approved IVRS - Inspection :*
04/10/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER F. SALDIVAR
04/19/2006 PLUMBING - GAS PRESSURE TEST FSALDIVA Approved IVRS - Inspection :*
04/19/2006 MECHANICAL - INTERMEDIATE FSALDIVA Approved IVRS - Inspection :*
04/19/2006 PLUMBING - INTERMEDIATE FSALDIVA Approved IVRS - Inspection :*
04/19/2006 ELECTRIC - INTERMEDIATE FSALDIVA Approved IVRS - Inspection :*
04/19/2006 FRAMING FSALDIVA Approved IVRS - Inspection :*
04/19/2006 STUCCO MESH FSALDIVA Approved IVRS - Inspection :*
05/05/2006 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection :*
05/05/2006 SHEET ROCK NAILING JRIVA Approved IVRS - Inspection :*
06/29/2006 MECHANICAL - FINAL JRIVA Approved IVRS - Inspection :*
06/29/2006 PLUMBING - FINAL JRIVA Approved IVRS - Inspection :*
06/29/2006 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection :*
06/29/2006 BUILDING - FINAL JRIVA Approved IVRS - Inspection :*
07/06/2006 PERMIT FINALED JWEATHER Approved