Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM05503
Permit Details
Apply Date:
10/28/2005
Applicant:
U S HOME OF ARIZONA *P *C
Description:
SFR TD# 16-36-93
Contractors:
- U S HOME OF ARIZONA *P *C
Permit Reviews
Permit Number - T05CM05503
Permit Status: C of o
Permit Description: SFR TD# 16-36-93
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/28/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/01/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05503
Permit Status: C of o
Permit Description: SFR TD# 16-36-93
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/28/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM05503
Permit Description: SFR TD# 16-36-93
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/03/2006 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection :* |
01/06/2006 | PLUMBING - SEWER HCS CONNECT | RCAMACHO | Approved | IVRS - Inspection :* |
01/17/2006 | ELECTRIC - UNDERGROUND | CTREVILL | Approved | IVRS - Inspection :* |
01/17/2006 | ELECTRIC - UFER | CTREVILL | Approved | IVRS - Inspection :* |
01/18/2006 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection :* |
01/18/2006 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection :* |
03/09/2006 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
03/09/2006 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection :* |
04/13/2006 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
04/13/2006 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
04/13/2006 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
04/13/2006 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection :* |
05/02/2006 | STUCCO MESH | JRIVA | Approved | IVRS - Inspection :* |
05/03/2006 | ELECTRIC - TEMPORARY SERVICE | JRIVA | Approved | IVRS - Inspection :* |
05/03/2006 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection :* |
05/04/2006 | PLUMBING - YARD WTR LINE/TEST | JRIVA | Approved | IVRS - Inspection :* |
05/04/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER J. RIVA |
05/05/2006 | FRAMING | JRIVA | Approved | IVRS - Inspection :* |
05/15/2006 | SHEET ROCK NAILING | FSALDIVA | Approved | IVRS - Inspection :* |
07/21/2006 | MECHANICAL - FINAL | JRIVA | Approved | IVRS - Inspection :* |
07/27/2006 | PLUMBING - GAS PRESSURE TEST | JRIVA | Approved | IVRS - Inspection :* |
07/27/2006 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
07/27/2006 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection :* |
07/27/2006 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
07/28/2006 | PERMIT FINALED | JWEATHER | Approved |