Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
10/25/2005
Applicant:
PEPPER VINER DEVELOPMENT COMPANY *C
Description:
SFR:TD16-15-22
Contractors:
  • PEPPER VINER DEVELOPMENT COMPANY *C

Permit Reviews

Permit Number - T05CM05442
Permit Status: C of o
Permit Description: SFR:TD16-15-22
Start Date Submittal Complete Date Status  
10/25/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 10/26/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM05442
Permit Status: C of o
Permit Description: SFR:TD16-15-22
Total Outstanding Activity Conditions - 1
Date Name
10/25/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM05442
Permit Description: SFR:TD16-15-22
Total Completed Inspections - 26
Date Description Inspector Results Comments
11/01/2005 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
11/01/2005 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
11/01/2005 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
11/14/2005 ELECTRIC - UNDERGROUND WNORTH Approved IVRS - Inspection :*
11/14/2005 ELECTRIC - UFER WNORTH Approved IVRS - Inspection :*
11/14/2005 BUILDING PRE-SLAB WNORTH Approved IVRS - Inspection :*
11/14/2005 STEM WALL/RETAINING WALL WNORTH Approved IVRS - Inspection :*
11/14/2005 EXCAVATION/LAYOUT REBAR & ZON WNORTH Approved IVRS - Inspection :*
12/22/2005 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*
1) TRUSS DAMAGED IN GARAGE
2) WEDGE SHIM UNDER LARGE BEAM WEST SODE TRAP BOTH SIDES
3) NEED CRIPPLES UNDER BEAM 1ST TO 2ND FLOOR
4) MISSED REAR SHEAR NAILING 2ND FLOOR
5) DRIVE NAILS HOME A35 AT BLOCKS KITCHEN SHEAR
6) NEED CORRECT TRUSS DRAWINGS
7) MISSED 3 PA. STRAPS 2-REAR, 1 ON WEST SIDE
12/22/2005 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
02/07/2006 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
02/07/2006 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
02/07/2006 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
02/09/2006 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
02/09/2006 FRAMING RFREIDIN Approved IVRS - Inspection :*
02/09/2006 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
02/09/2006 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
02/24/2006 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
02/24/2006 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
02/27/2006 TEP CLEARANCE - AM JKOZUCH Approved ECO
03/06/2006 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
1) RECEPTACLE BURRIED 1ST FLOOR FRONT EAST BEDROOM
04/26/2006 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
04/26/2006 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
04/26/2006 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
04/26/2006 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
04/27/2006 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
COFO_05-05-2006.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
SITE PLAN_10-26-2005.TIF CONSTRPLANS VIEW