Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address NEW:
7387 E TANQUE VERDE RD
Apply Date:
10/13/2005
Applicant:
METROP PERMIT EXPRESS
Description:
OFFICE BUILDING:NEW
Contractors:
  • VENTURE WEST INC

Permit Reviews

Permit Number - T05CM05200
Permit Status: C of o
Permit Description: OFFICE BUILDING:NEW
Start Date Submittal Complete Date Status  
02/24/2006 3RD PARTY REVIEW-REVISION/OTHER 03/14/2006 COMPLETED Review Details
03/11/2006 3RD PARTY REVIEW-REVISION/OTHER-2ND 03/23/2006 COMPLETED Review Details
03/31/2006 3RD PARTY REVIEW-REVISION/OTHER 04/19/2006 COMPLETED Review Details
10/13/2005 PLANS OK TO SUBMIT - 3RD PARTY 10/18/2005 COMPLETED Review Details
10/18/2005 3RD PARTY REVIEW-COMMERCIAL 12/13/2005 COMPLETED Review Details
12/13/2005 POST 3RD PARTY REVIEW 12/28/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM05200
Permit Status: C of o
Permit Description: OFFICE BUILDING:NEW
Total Outstanding Activity Conditions - 1
Date Name
10/13/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM05200
Permit Description: OFFICE BUILDING:NEW
Total Completed Inspections - 35
Date Description Inspector Results Comments
01/20/2006 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
WATER TEST UNDERGROUND THRU BUILDING & HCS OK
PIPE WRAPS OK
02/03/2006 BUILDING PRE-SLAB JCAGLE Approved IVRS - Inspection :*
02/06/2006 EXCAVATION/LAYOUT REBAR & ZON JCAGLE Approved IVRS - Inspection :*
1) CANOPY PEDESTALS AT EAST SIDE OF BLDG
03/14/2006 EXT METAL CLIPS/EXT SHEATHING JCAGLE Approved IVRS - Inspection :*
03/15/2006 ROOF NAILING JCAGLE Approved IVRS - Inspection :*
04/07/2006 FRAMING JBURGE Approved IVRS - Inspection :*
04/11/2006 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
04/12/2006 ELECTRIC - OUTDOOR LIGHTING RSUBA Approved IVRS - Inspection :*
04/27/2006 STUCCO MESH JCAGLE Approved IVRS - Inspection :*
04/28/2006 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*
SOFFIT CANS & WALLS
05/12/2006 TEP CLEARANCE - AM JWEATHER Approved CEC TO TERM CAN PER R. HOLLANDER
05/31/2006 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
06/27/2006 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) OK FOR CEILING TILES
06/27/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
06/28/2006 TEP CLEARANCE - PM JWEATHER Approved TMPP CLEARED PER R. HOLLANDER
06/30/2006 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
NO VDV CABELING TO GO IN
OK TO TILE.
06/30/2006 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
07/21/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
07/21/2006 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
07/21/2006 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection :*
07/21/2006 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
07/21/2006 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection :*
07/21/2006 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
07/21/2006 FIRE - FINAL LTHOMAS Approved
07/21/2006 SIGN - FINAL JSONKIN Approved IVRS - Inspection :*
07/25/2006 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
07/26/2006 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
07/26/2006 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
07/26/2006 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection :*
07/31/2006 ENGINEERING - FINAL JBRUCKME Approved
08/07/2006 LANDSCAPE - FINAL ACONNOR Approved
08/07/2006 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
08/07/2006 ELECTRIC - CONSTRUCTION POWER RHOLLAND Approved IVRS - Inspection :*
08/08/2006 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
08/08/2006 SITE - SEWER BBENEDON Approved SITE SEWER WAS INSPECTED UNDER SHELL PERMIT AND IS NOT APPLICABLE TO THIS ACTIVITY.