Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM04778
Permit Details
Apply Date:
09/19/2005
Applicant:
D R HORTON HOMES
Description:
TOWNHOUSE:TD#16-31-27
Contractors:
- D R HORTON HOMES
Permit Reviews
Permit Number - T05CM04778
Permit Status: Final
Permit Description: TOWNHOUSE:TD#16-31-27
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/19/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 09/20/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04778
Permit Status: Final
Permit Description: TOWNHOUSE:TD#16-31-27
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/19/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM04778
Permit Description: TOWNHOUSE:TD#16-31-27
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2005 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :*WATER TEST UNDERGROUND THRU BUILDING & 2 WAY CLEANOUT OK NEED TO VIEW PIPE WRAPS PRIOR TO CONCRETE. |
11/21/2005 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* |
11/21/2005 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
11/30/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
11/30/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
12/01/2005 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
12/08/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :*INSIDE FIREWALL |
12/23/2005 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :*COMPLETE HORIZONTAL BRACING ( RAT RUNS) OF TRUSSES PER PLAN. HORIZONTAL BRACING TO BE CONTINUOUS THOUGH UNIT. ( AT DISSIMILAR TRUSSES -BLOCK AND ?AIL) |
12/23/2005 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection :* |
02/02/2006 | ELECTRIC - CABLE DROP | RSUBA | Approved | IVRS - Inspection :* |
02/03/2006 | ELECTRIC - TEMPORARY SERVICE | RSUBA | Approved | IVRS - Inspection :* |
02/06/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
02/15/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
02/15/2006 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
02/15/2006 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
02/15/2006 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
02/23/2006 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
02/23/2006 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
02/24/2006 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :* |
04/14/2006 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* |
05/18/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
05/24/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* THERE IS NO GAS PIPED TO CLOTHES DRYER STRAINER MISSING IN SHOWER. |
07/27/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
07/28/2006 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
07/31/2006 | PERMIT FINALED | BFLORES | Approved |