Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
09/02/2005
Applicant:
D R HORTON HOMES
Description:
TOWNHOUSE:TD#16-31-29
Contractors:
  • D R HORTON HOMES

Permit Reviews

Permit Number - T05CM04578
Permit Status: C of o
Permit Description: TOWNHOUSE:TD#16-31-29
Start Date Submittal Complete Date Status  
09/02/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 09/23/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM04578
Permit Status: C of o
Permit Description: TOWNHOUSE:TD#16-31-29
Total Outstanding Activity Conditions - 1
Date Name
09/02/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM04578
Permit Description: TOWNHOUSE:TD#16-31-29
Total Completed Inspections - 26
Date Description Inspector Results Comments
11/04/2005 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection :*GARDEN CENTER
11/04/2005 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*OK TO COVER UFER
11/04/2005 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection :*
11/07/2005 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
11/07/2005 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999* PIPE WRAP TO COVER AM PIPING IN POUR
PAY SPECIAL ATTENTION TO HORIZONTAL PIPING IN FOOTIN
11/18/2005 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection :*FIREWALL
12/02/2005 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
12/02/2005 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection :*
12/29/2005 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*OK TO COVER YARDWATER OK TO COVER SEWER
12/29/2005 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
12/30/2005 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :
See detailed listing on site.| 999*FHA
12/30/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*CHECK B-1 VENTS
WATER HTR. VENT & FURNACE
CHECK EXCESSIVE LENGTH OF FLEX ON FURN.
12/30/2005 FRAMING AMATHIES Approved IVRS - Inspection :*
01/03/2006 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
01/04/2006 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*CORRECTION MADE OK. OK TO COVER ALL AREAS
01/09/2006 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
01/13/2006 STUCCO MESH LHANLY Approved IVRS - Inspection :*
02/02/2006 ELECTRIC - TEMPORARY SERVICE RSUBA Approved IVRS - Inspection :*
02/02/2006 ELECTRIC - CABLE DROP RSUBA Approved IVRS - Inspection :*
02/03/2006 TEP CLEARANCE - AM JKOZUCH Approved ECO
03/09/2006 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved IVRS - Inspection :*
03/29/2006 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
03/29/2006 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
04/25/2006 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
04/25/2006 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
04/26/2006 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
SITE PLAN_09-09-2005.TIF CONSTRPLANS VIEW
C OF O_05-05-2006.TIF CERT OF OCC VIEW