Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM04423
Permit Details
Apply Date:
08/25/2005
Applicant:
D R HORTON HOMES
Description:
TOWNHOUSE:TD#16-31-26
Contractors:
- D R HORTON HOMES
Permit Reviews
Permit Number - T05CM04423
Permit Status: Expired
Permit Description: TOWNHOUSE:TD#16-31-26
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/25/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 08/25/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04423
Permit Status: Expired
Permit Description: TOWNHOUSE:TD#16-31-26
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/25/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM04423
Permite Description: TOWNHOUSE:TD#16-31-26
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/16/2006 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* IMPROPER GRADING REAR YARD - FINISH WORK - GROND MUST SLOPE AWAY FROM BUILDING 3' MIN |
12/22/2005 | MECHANICAL - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* FURN/WATER HTR. VENT (B-1 VENT) PIPE PENETRATIONS AT ROOF VENT - PIPE IS IN CONTACT W/FELT ROOF MAT TRIM EXCESS FELT AS NECESSARY |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM04423
Permit Description: TOWNHOUSE:TD#16-31-26
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2005 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
10/11/2005 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :*20' REBAR UFER REVISE LETTER FOR UFER TO REFLECT CODE ACCURATLY PER NEC ART 250 |
10/11/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
10/11/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
11/10/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* INSIDE PARTY WALL OK |
11/21/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
11/21/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
12/16/2005 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* 1) PLEASE REMOVE DEBRIS, ALL LARGE CHUNKS OF MATERIAL AND PROVIDE GOOD FILL MATERIAL |
12/16/2005 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* |
12/22/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 14 PSI TEST FROM METER TO STOVE, WATER HEATER, FURNACE -- OK |
12/22/2005 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF & WATER DIST. -- OK CLOSET FLANGES - OK |
12/22/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
12/27/2005 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :*VERIFY UFER TERM. INTO PANEL # 4 STR. FOR GAS BOND. OK WALLS & CEILINGS |
12/28/2005 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
12/28/2005 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
02/02/2006 | ELECTRIC - TEMPORARY SERVICE | RSUBA | Approved | IVRS - Inspection :* |
02/02/2006 | ELECTRIC - CABLE DROP | RSUBA | Approved | IVRS - Inspection :* |
02/03/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | |
03/09/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
03/09/2006 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* |
03/15/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* DO NOT CALL IN MORE THAN 5 UNITS IN ONE DAY |
03/16/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |