Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM04290
Permit Details
Apply Date:
08/17/2005
Applicant:
BARNETT BUILDING AND DEVELOPMENT
Description:
INTERIOR REMODEL
Contractors:
- BARNETT BUILDING AND DEVELOPMENT
Permit Reviews
Permit Number - T05CM04290
Permit Status: Final
Permit Description: INTERIOR REMODEL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/17/2005 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 08/23/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04290
Permit Status: Final
Permit Description: INTERIOR REMODEL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/17/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM04290
Permit Description: INTERIOR REMODEL
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/29/2005 | PLUMBING - GAS PRESSURE TEST | RCAMACHO | Approved | IVRS - Inspection :* |
08/29/2005 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
08/29/2005 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection :* |
09/21/2005 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
09/21/2005 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
09/21/2005 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
09/27/2005 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
11/29/2005 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
12/05/2005 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTERIOR GFCI OUTLETS NOT INSTALLED 2) INSTALL GAS BOND CLAMP 3) LOWER CLEANOUTS TO GRADE 4) INSTALL ANTI-SIPHON TO HOSE BIBS VACCUM BREAKER 5) INSTALL EXTERIOR LIGHT FIXTURE FRONT ENTRY DOOR 6) ISLAND NOT GFCI PROTECTED 7) INSTALL CLEANOUT COVER WEST BATH CLOSET 8) WEST BATH ELECTRIC NOT MADE UP 9) GREAT ROOM OUTLETS TEST OPEN GROUND 10) NO POWER 11) NO SMOKE ALARM EAST BEDROOM 12) INSTALL KITCHEN HOOD 13) PROVIDE ACCESS TO ROOF TOP |
12/05/2005 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/05/2005 | PLUMBING - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/05/2005 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/15/2006 | PLUMBING - GAS PRESS TEST FNL | RCAMACHO | Approved | IVRS - Inspection :* |
03/16/2006 | PERMIT FINALED | JWEATHER | Approved |