Permit: T05CM04142
Permit Details
Apply Date:
08/08/2005
Applicant:
DONALD CLEMENS
Description:
CARPORT INTO MASTERBED AND BATH
Permit Reviews
Permit Number - T05CM04142
Permit Status: Final
Permit Description: CARPORT INTO MASTERBED AND BATH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/08/2005 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 08/08/2005 | COMPLETED |
08/08/2005 | RESIDENTIAL BLDG/ZONING/ENGINE/NPPO | 09/20/2005 | COMPLETED |
11/29/2005 | RESUBMITTAL | 12/01/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04142
Permit Status: Final
Permit Description: CARPORT INTO MASTERBED AND BATH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/08/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM04142
Permit Description: CARPORT INTO MASTERBED AND BATH
Total Completed Inspections - 13
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/22/2005 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 10' HEAD WATER TEST TO DWV SYSTEM COPPER OK 2) BLOCK REGISTERS 3-SIDES 3) OVERSPAN BATH NORTH WALL 4) SECURE ALL ROMEX PROPERLY 5) ROMEX IN HALL CANS MUST TERMINATE IN BOX 6) PROVIDE COPPER BOND 7) LAUNDRY ROOM ELECTRIC NOT MADE UP 8) EXTEND WATER HEATER TPR VALVE TO EXTERIOR 9) MAKE UP ALL SWITCH GROUNDS PIG TAIL 10) EXTERIOR LIGHT FIXTURE MISSING REAR DOOR 11) USE APPROVED CEILING FAN BOX 12) BATH EXHAUST NOT INSTALLED 13) STOPPED INSPECTION |
12/22/2005 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/22/2005 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/22/2005 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/22/2005 | FRAMING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/22/2005 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
01/12/2006 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
02/15/2006 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* 1) NOTE: MAIN SERVICE PANEL MUST BE RELOCATED FOR 36" MINIMUM WORKING CLEARANCES PRIOR TO FINAL INSPECTIONS |
03/15/2006 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* |
03/15/2006 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
03/15/2006 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |
03/15/2006 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
03/16/2006 | PERMIT FINALED | WNORTH | Approved |