Permit: T05CM03719
Permit Details
Apply Date:
07/13/2005
Applicant:
ALLIED HOMES INC
Description:
SFR:TD#16-27-00
Contractors:
- ALLIED HOMES INC
Outstanding Activity Conditions
Permit Number - T05CM03719
Permit Status: Expired
Permit Description: SFR:TD#16-27-00
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/13/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM03719
Permite Description: SFR:TD#16-27-00
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| LANDSCAPE - FINAL | N/A | Not Inspected |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM03719
Permit Description: SFR:TD#16-27-00
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2005 | PLUMBING - SEWER HCS CONNECT | ROHAVER | Approved | IVRS - Inspection :* |
| 09/15/2005 | PLUMBING - ROUGH, SOIL | ROHAVER | Approved | IVRS - Inspection :* |
| 09/28/2005 | EXCAVATION/LAYOUT REBAR & ZON | ROHAVER | Approved | IVRS - Inspection :* |
| 09/28/2005 | ELECTRIC - UFER | ROHAVER | Approved | IVRS - Inspection :* |
| 09/28/2005 | BUILDING PRE-SLAB | ROHAVER | Approved | IVRS - Inspection :* |
| 10/26/2005 | ROOF NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 10/28/2005 | EXT METAL CLIPS/EXT SHEATHING | ROHAVER | Approved | IVRS - Inspection :* |
| 12/15/2005 | ELECTRIC - TEMPORARY SERVICE | ROHAVER | Approved | IVRS - Inspection :* |
| 12/15/2005 | ELECTRIC - CABLE DROP | ROHAVER | Approved | IVRS - Inspection :* |
| 12/16/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 12/16/2005 | U VALUE FOR WINDOW | IVR USER | Approved | IVRS - RI canceled |
| 12/16/2005 | STUCCO MESH | IVR USER | Approved | IVRS - RI canceled |
| 12/16/2005 | PLUMBING - GAS PRESSURE TEST | IVR USER | Approved | IVRS - RI canceled |
| 12/16/2005 | MECHANICAL - INTERMEDIATE | IVR USER | Approved | IVRS - RI canceled |
| 12/16/2005 | PLUMBING - INTERMEDIATE | IVR USER | Approved | IVRS - RI canceled |
| 12/16/2005 | ELECTRIC - INTERMEDIATE | IVR USER | Approved | IVRS - RI canceled |
| 12/16/2005 | FRAMING | IVR USER | Approved | IVRS - RI canceled |
| 01/06/2006 | PLUMBING - YARD WTR LINE/TEST | ROHAVER | Approved | IVRS - Inspection :* |
| 01/27/2006 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 04/19/2006 | MECHANICAL - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
| 04/19/2006 | PLUMBING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
| 04/19/2006 | ELECTRIC - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
| 04/19/2006 | BUILDING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |