Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM03710
Permit Details
Status:
C of o
Type:
DUPLEX NEW
Address:
8697 E PLACITA MORELIA #01
Address NEW:
8697 E PLACITA MORELIA #01
Apply Date:
07/13/2005
Applicant:
GOLDSTEIN CONSTRUCTION MANAGEMEN
Description:
DUPLEX:TD#16-36-37
Contractors:
- GOLDSTEIN CONSTRUCTION MANAGEMEN
Permit Reviews
Permit Number - T05CM03710
Permit Status: C of o
Permit Description: DUPLEX:TD#16-36-37
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/13/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/14/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03710
Permit Status: C of o
Permit Description: DUPLEX:TD#16-36-37
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/13/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM03710
Permit Description: DUPLEX:TD#16-36-37
Total Completed Inspections - 29
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2005 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :**50 PSI AIR TEST FROM METER TO BUILDING STUB UP OK NEED TO SEE METER & BUILDING |
| 10/28/2005 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :**WATER TEST UNDERGROUND FROM BUILDING THRU 2 WAY CLEANOUT OK |
| 11/21/2005 | ELECTRIC - UFER | RSUBA | Approved | IVRS - Inspection :* |
| 11/21/2005 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
| 11/21/2005 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection :* |
| 11/21/2005 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
| 02/21/2006 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 05/10/2006 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
| 05/10/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 05/10/2006 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF OK WATER PIPING OK CLOSET FLANGES OK |
| 05/10/2006 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
| 05/11/2006 | ELECTRIC - ABOVE CEILING | RSUBA | Approved | IVRS - Inspection :* |
| 05/11/2006 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :* |
| 05/15/2006 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
| 05/15/2006 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
| 06/13/2006 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 08/14/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* 1. GAVE G.C HANDOUT FROM PIMA COUNTY ABOUT ADDRESSING REQUIREMENTS. 2. OK TO COVER SEWER |
| 09/12/2006 | ELECTRIC - TEMPORARY SERVICE | RMAJUTA | Approved | IVRS - Inspection :* |
| 09/12/2006 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection :* |
| 09/13/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR UNITS #1 & #2 PER R. MAJUTA |
| 10/10/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 10/10/2006 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* |
| 10/10/2006 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 10/11/2006 | MECHANICAL - UNDERGROUND | JMILITEL | Approved | |
| 10/11/2006 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection :* |
| 10/11/2006 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
| 10/12/2006 | PERMIT FINALED | BFLORES | Approved | |
| 10/12/2006 | BUILDING ABOVE CEILING | GDABBS | Approved | |
| 10/12/2006 | ELECTRIC - UNDERGROUND | RSUBA | Approved |