Permit: T05CM03572
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
10454 E RITA RANCH CROSSING CI
Address NEW:
10454 E RITA RANCH CROSSING CI
Apply Date:
07/08/2005
Applicant:
PEPPER VINER DEVELOPMENT COMPANY *C
Description:
SFR:TD#16-14-57
Contractors:
- PEPPER VINER DEVELOPMENT COMPANY *C
Permit Reviews
Permit Number - T05CM03572
Permit Status: Final
Permit Description: SFR:TD#16-14-57
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/08/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/08/2005 | COMPLETED |
| 07/28/2005 | REVISION - SITE | 07/28/2005 | COMPLETED |
| 12/30/2005 | REVISION - WALK THRU | 12/30/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03572
Permit Status: Final
Permit Description: SFR:TD#16-14-57
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/08/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM03572
Permit Description: SFR:TD#16-14-57
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2005 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* |
| 11/01/2005 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
| 11/01/2005 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | IVRS - Inspection :* |
| 12/29/2005 | EXT METAL CLIPS/EXT SHEATHING | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL 2ND FLOOR OVER SHEARWALL 10D'S 6" ON CENTER 2) SHEAR TRANSFER OVER BALLOON FRAME IN LIVING ROOM 3) H.D. IN KITCHEN 4) STRAP OVER KITCHEN H.D. 5) PROVIDE SHEAR DETAIL FOR OPTIONAL BACK PATIO |
| 12/29/2005 | ROOF NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 01/17/2006 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/17/2006 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/18/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 02/10/2006 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/10/2006 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/10/2006 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/10/2006 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/10/2006 | FRAMING | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/10/2006 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :* |
| 03/09/2006 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/03/2006 | ELECTRIC - UFER | RFREIDIN | Approved | |
| 05/03/2006 | U VALUE FOR WINDOW | RFREIDIN | Approved | |
| 05/03/2006 | BUILDING PRE-SLAB | RFREIDIN | Approved | |
| 05/03/2006 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | |
| 05/03/2006 | OUTDOOR LIGHTING FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/03/2006 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/03/2006 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/03/2006 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/03/2006 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 10/11/2006 | PERMIT FINALED | LJACKSON | Approved |