Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Si_xpire
Type:
SINGLE FAMILY NEW
Apply Date:
07/06/2005
Applicant:
DOUCETTE HOMES INC *C
Description:
SFR:TD#16-22-45
Contractors:
  • DOUCETTE HOMES INC *C

Permit Reviews

Permit Number - T05CM03471
Permit Status: Si_xpire
Permit Description: SFR:TD#16-22-45
Start Date Submittal Complete Date Status  
07/06/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 07/12/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM03471
Permit Status: Si_xpire
Permit Description: SFR:TD#16-22-45
Total Outstanding Activity Conditions - 2
Date Name
07/06/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
07/06/2005 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Outstanding Inspections

Permit Status: Si_xpire
Permit Number: T05CM03471
Permite Description: SFR:TD#16-22-45
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
PERMIT FINALED N/A Not Inspected

Completed Inspections

Permit Status: Si_xpire
Permit Number: T05CM03471
Permit Description: SFR:TD#16-22-45
Total Completed Inspections - 30
Date Description Inspector Results Comments
12/19/2005 PLUMBING - SEWER HCS CONNECT HPEDROZA Approved IVRS - Inspection :*
12/19/2005 PLUMBING - YARD WTR LINE/TEST HPEDROZA Approved IVRS - Inspection :*
12/19/2005 PLUMBING - ROUGH, SOIL HPEDROZA Approved IVRS - Inspection :*
12/22/2005 ELECTRIC - UFER HPEDROZA Approved IVRS - Inspection :*
12/22/2005 BUILDING PRE-SLAB HPEDROZA Approved IVRS - Inspection :*
12/22/2005 EXCAVATION/LAYOUT REBAR & ZON HPEDROZA Approved IVRS - Inspection :*
02/14/2006 ROOF NAILING HPEDROZA Approved IVRS - Inspection :*
02/14/2006 EXT METAL CLIPS/EXT SHEATHING HPEDROZA Approved IVRS - Inspection :*
03/03/2006 ELECTRIC - TEMPORARY SERVICE EDURAZO Approved
03/03/2006 ELECTRIC - CABLE DROP EDURAZO Approved IVRS - Inspection :*
03/06/2006 TEP CLEARANCE - AM JWEATHER Approved OK ECO PER E. DURAZO
03/09/2006 PLUMBING - GAS PRESSURE TEST CTREVILL Approved IVRS - Inspection :*
03/09/2006 MECHANICAL - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
03/09/2006 PLUMBING - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
03/09/2006 ELECTRIC - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
03/09/2006 FRAMING CTREVILL Approved IVRS - Inspection :*
03/09/2006 FRAMING CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOWN FIRE BLOCKS
2) FIRE BLOCKS MISSING
3) PEX TOO CLOSE TO CAN
4) SECURE VTR
03/09/2006 PLUMBING - GAS PRESSURE TEST CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/09/2006 MECHANICAL - INTERMEDIATE CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/09/2006 PLUMBING - INTERMEDIATE CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/09/2006 ELECTRIC - INTERMEDIATE CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/09/2006 U VALUE FOR WINDOW CTREVILL Approved IVRS - Inspection :*
03/09/2006 STUCCO MESH CTREVILL Approved IVRS - Inspection :*
03/22/2006 SHEET ROCK NAILING EDURAZO Approved IVRS - Inspection :*
06/16/2006 MECHANICAL - FINAL CTREVILL Approved IVRS - Inspection :*
06/16/2006 PLUMBING - FINAL CTREVILL Approved IVRS - Inspection :*
06/16/2006 OUTDOOR LIGHTING FINAL CTREVILL Approved IVRS - Inspection :*
06/16/2006 ELECTRIC - FINAL CTREVILL Approved IVRS - Inspection :*
06/16/2006 BUILDING - FINAL CTREVILL Approved IVRS - Inspection :*
06/19/2006 PLUMBING - GAS PRESS TEST FNL CTREVILL Approved