Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM03470
Permit Details
Apply Date:
07/06/2005
Applicant:
DOUCETTE HOMES INC *C
Description:
SFR:TD#16-22-44
Contractors:
- DOUCETTE HOMES INC *C
Permit Reviews
Permit Number - T05CM03470
Permit Status: C of o
Permit Description: SFR:TD#16-22-44
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/06/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/13/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03470
Permit Status: C of o
Permit Description: SFR:TD#16-22-44
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/06/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM03470
Permit Description: SFR:TD#16-22-44
Total Completed Inspections - 31
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/19/2005 | PLUMBING - SEWER HCS CONNECT | HPEDROZA | Approved | IVRS - Inspection :* |
12/19/2005 | PLUMBING - YARD WTR LINE/TEST | HPEDROZA | Approved | IVRS - Inspection :* |
12/19/2005 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection :* |
12/22/2005 | ELECTRIC - UFER | HPEDROZA | Approved | IVRS - Inspection :* |
12/22/2005 | BUILDING PRE-SLAB | HPEDROZA | Approved | IVRS - Inspection :* |
12/22/2005 | EXCAVATION/LAYOUT REBAR & ZON | HPEDROZA | Approved | IVRS - Inspection :* |
02/14/2006 | ROOF NAILING | HPEDROZA | Approved | IVRS - Inspection :* |
02/14/2006 | EXT METAL CLIPS/EXT SHEATHING | HPEDROZA | Approved | IVRS - Inspection :* |
03/03/2006 | ELECTRIC - TEMPORARY SERVICE | EDURAZO | Approved | |
03/03/2006 | ELECTRIC - CABLE DROP | EDURAZO | Approved | IVRS - Inspection :* |
03/06/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | OK ECO PER E. DURAZO |
03/09/2006 | PLUMBING - GAS PRESSURE TEST | CTREVILL | Approved | IVRS - Inspection :* |
03/09/2006 | MECHANICAL - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
03/09/2006 | PLUMBING - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
03/09/2006 | ELECTRIC - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
03/09/2006 | FRAMING | CTREVILL | Approved | IVRS - Inspection :* |
03/09/2006 | FRAMING | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK MECH 2) FIREBLOCKS BLOWN AND MISSING 3) NO DWV 4) SECURE VTR 5) AB MISSING BED 2 |
03/09/2006 | PLUMBING - GAS PRESSURE TEST | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/09/2006 | MECHANICAL - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/09/2006 | PLUMBING - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/09/2006 | ELECTRIC - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/09/2006 | U VALUE FOR WINDOW | CTREVILL | Approved | IVRS - Inspection :* |
03/09/2006 | STUCCO MESH | CTREVILL | Approved | IVRS - Inspection :* |
03/23/2006 | SHEET ROCK NAILING | CTREVILL | Approved | IVRS - Inspection :* |
06/29/2006 | MECHANICAL - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
06/29/2006 | PLUMBING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
06/29/2006 | ELECTRIC - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
06/30/2006 | BUILDING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
07/05/2006 | PERMIT FINALED | BFLORES | Approved | |
07/05/2006 | PLUMBING - GAS PRESS TEST FNL | CTREVILL | Approved | |
07/05/2006 | OUTDOOR LIGHTING FINAL | CTREVILL | Approved |