Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM03349
Permit Details
Apply Date:
07/05/2005
Applicant:
PULTE HOME CORPORATION ARIZONA *C
Description:
SFR:TD 16-28-18
Contractors:
- PULTE HOME CORPORATION ARIZONA *C
Permit Reviews
Permit Number - T05CM03349
Permit Status: Final
Permit Description: SFR:TD 16-28-18
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/05/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/07/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03349
Permit Status: Final
Permit Description: SFR:TD 16-28-18
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/05/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM03349
Permit Description: SFR:TD 16-28-18
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2005 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
10/19/2005 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
10/20/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
11/08/2005 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | IVRS - Inspection :* |
11/08/2005 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* |
11/21/2005 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* |
11/21/2005 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
11/21/2005 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection :* |
12/08/2005 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
12/08/2005 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :* |
12/29/2005 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSED NAILING ON ROOF 2) CHANGE OUT HANGERS AT ROOF GIRDER USE HUS26 3" POCKET 16DS 3) FRONT AND REAR PORCH/SHED NAIL DECK TO LEDGER 4) HEADER AT ELECTRIC PANEL 5) WRONG NAILS IN P.A.'S 6) SHIM 3 PT FLOOR TRUSSES 7) 4 2 X 6 UNDER BEAM 1ST FLOOR 8) NAIL ROOF TO LARGE SHEAR PANELS ROOF |
12/29/2005 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
02/28/2006 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
02/28/2006 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
02/28/2006 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
02/28/2006 | FRAMING | RFREIDIN | Approved | IVRS - Inspection :* |
03/20/2006 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
03/20/2006 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection :* |
06/01/2006 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
06/01/2006 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
06/01/2006 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
06/01/2006 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
06/02/2006 | PERMIT FINALED | JWEATHER | Approved |