Permit: T05CM03276
Permit Details
Apply Date:
07/01/2005
Applicant:
BAY CITY INVESTMENTS
Description:
TOWNHOUSE: TD#16-28-21
Permit Reviews
Permit Number - T05CM03276
Permit Status: C of o
Permit Description: TOWNHOUSE: TD#16-28-21
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/01/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/05/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03276
Permit Status: C of o
Permit Description: TOWNHOUSE: TD#16-28-21
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/01/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM03276
Permit Description: TOWNHOUSE: TD#16-28-21
Total Completed Inspections - 29
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2006 | BUILDING - PROGRESS | AMATHIES | Approved | IVRS - Inspection :* |
| 02/03/2006 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :*SOIL WATER TEST IS OK HCS CONNECTION IS OK |
| 02/03/2006 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection :* |
| 02/06/2006 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
| 02/06/2006 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
| 02/06/2006 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
| 02/21/2006 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* CONTRACTOR RESPONSIBLE TO PROVIDE CLEAN FILL |
| 03/10/2006 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 03/10/2006 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection :* |
| 03/10/2006 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection :* |
| 03/17/2006 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
| 03/17/2006 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 03/20/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 03/22/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/23/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/05/2006 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 04/06/2006 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection :* |
| 04/07/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER D. SANTACRUZ |
| 04/17/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 04/17/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 04/17/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 04/18/2006 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* OK C OF O |
| 04/19/2006 | PERMIT FINALED | BFLORES | Approved | |
| 04/19/2006 | MECHANICAL - HOODS | CWILLIAM | Approved | |
| 04/19/2006 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | |
| 04/19/2006 | ELECTRIC - CABLE DROP | DSANTACR | Approved | |
| 04/19/2006 | ELECTRIC - UFER | DSANTACR | Approved | |
| 04/19/2006 | U VALUE FOR WINDOW | LHANLY | Approved | |
| 04/19/2006 | STEM WALL/RETAINING WALL | LHANLY | Approved |