Permit: T05CM03076
Permit Details
Apply Date:
06/23/2005
Applicant:
PULTE HOME CORPORATION ARIZONA *C
Description:
SFR: TD#16-28-20
Contractors:
- PULTE HOME CORPORATION ARIZONA *C
Permit Reviews
Permit Number - T05CM03076
Permit Status: C of o
Permit Description: SFR: TD#16-28-20
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/23/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 06/28/2005 | COMPLETED |
07/13/2005 | REVISION | 07/13/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03076
Permit Status: C of o
Permit Description: SFR: TD#16-28-20
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/23/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM03076
Permit Description: SFR: TD#16-28-20
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2005 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* |
08/01/2005 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
08/01/2005 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection :* |
09/23/2005 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
09/23/2005 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | IVRS - Inspection :* |
09/23/2005 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* |
09/23/2005 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
09/29/2005 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
09/29/2005 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
09/30/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | |
10/03/2005 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | AT INTERMEDIATE, CHECK GARAGE STRAP SPACING AT BEAM 48" ON CENTER |
10/24/2005 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
10/24/2005 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
11/14/2005 | FRAMING | RFREIDIN | Approved | IVRS - Inspection :* 1) NO GAS-ALL ELECTRIC |
11/14/2005 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection :* |
11/14/2005 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :* |
11/14/2005 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
11/14/2005 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
12/30/2005 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NOT H20 BOND SYSTEM TO BE LABELED IN SERVICE PANEL 2) LABEL DISONNECT IN ATTIC FOR HEAT STRIP SIZE 3) INSTALL BUSHINGS IN CAN LIGHTS IN ATTIC 4) NO POWER IN MAJORITY OF MASTER BEDROOM RECEPTACLES 5) H20 HEATER AND SOLAR EQUIPMENT NOT INSTALLED 6) MISSING 1ST FLOOR BATH LIGHT FIXTURE 7) APPLIANCES NOT INSTALLED 8) ADDRESS NUMBER 9) ANTI-SIPHON AT HOSE BIB |
12/30/2005 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/30/2005 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/30/2005 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
01/12/2006 | PERMIT FINALED | JWEATHER | Approved |