Permit: T05CM02389
Permit Details
Apply Date:
05/25/2005
Applicant:
N/A
Description:
ADDITION: EXHAUST HOOD AND GASLINE STEEL COLUMNS AT HOOD T00VL00045
Contractors:
- PRECISION STAINLESS MFG ,
Permit Reviews
Permit Number - T05CM02389
Permit Status: Expired
Permit Description: ADDITION: EXHAUST HOOD AND GASLINE
STEEL COLUMNS AT HOOD T00VL00045
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/25/2005 | COMMERCIAL TI | 07/20/2005 | COMPLETED |
08/30/2005 | REVISION - WALK THRU | 08/30/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02389
Permit Status: Expired
Permit Description: ADDITION: EXHAUST HOOD AND GASLINE
STEEL COLUMNS AT HOOD T00VL00045
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/25/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM02389
Permite Description: ADDITION: EXHAUST HOOD AND GASLINE
STEEL COLUMNS AT HOOD T00VL00045
Total Outstanding Inspections - 5
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/04/2005 | ELECTRIC - ABOVE CEILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO PLANS, PERMIT, OR PERSONNEL PRESENT FOR INSPECTION |
08/19/2005 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPORT CONDUIT AND M/C CABLE AND FLEX CONDUIT AS PER CODES 2) USE APPROVED FITTINGS FOR M/C CABLE 3) SUPPORT BOXES 4) WE NEED A DIAGRAM OF THE HOOD AND MAKE-UP AIR INTER LOCK. PLAN TO BE STAMPED APPROVAL 5) PLEASE GROUND ALL JUNCTION BOXES |
08/19/2005 | FIRE SPKLR - FINAL | N/A | Denied | SUB-CONTRACTOR NOT READY |
08/19/2005 | FIRE - FINAL | N/A | Denied | SUB-CONTRACTOR NOT READY |
10/05/2005 | BUILDING - FINAL | N/A | Partial Approval | IVRS - Inspection :* THIS INSPECTION DOES NOT APPLY TO THIS ACTIVITY PER S LONG |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM02389
Permit Description: ADDITION: EXHAUST HOOD AND GASLINE
STEEL COLUMNS AT HOOD T00VL00045
Total Completed Inspections - 10
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/19/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
09/01/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK 2) GAS SHUT OFF VALVES OK 3) ALL CORRECTIONS HAVE BEEN MADE |
09/01/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | |
09/01/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | |
09/01/2005 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | |
09/06/2005 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* 1) CHECKED FIRE WRAP ON GREASE DUCT 2) NOTE 4800 CFM EVAP COOLER IS NOT EXISTING AS THE PLANS STATE. COOLER AND ALL RELATED DUCT WORK ARE NEW. PLANS WERE APPROVED IN ERROR. MAKE UP AIR MUST BE HEATER. PLEASE HAVE PLANS REVISED SHOWING THE PROPER DESCRIPTION OF WORK |
09/28/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
09/28/2005 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | |
10/05/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :*THIS INSP. DOES NOT SEEM TO APPLY. THERE ARE NO FRAMING DETAILS |
10/05/2005 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :*THIS INSPECTION DOES NOT SEEM TO APPLY TO THIS PERMIT. NO DETAILS PROVIDED |