Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address NEW:
1481 W BEANTREE LN
Apply Date:
05/24/2005
Applicant:
K B HOME OF TUCSON *C
Description:
SFR TD#15-38-44
Contractors:
  • K B HOME OF TUCSON *C

Permit Reviews

Permit Number - T05CM02368
Permit Status: Final
Permit Description: SFR TD#15-38-44
Start Date Submittal Complete Date Status  
02/07/2006 REVISION - - 1ST 02/10/2006 COMPLETED Review Details
05/24/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 06/02/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM02368
Permit Status: Final
Permit Description: SFR TD#15-38-44
Total Outstanding Activity Conditions - 1
Date Name
05/24/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM02368
Permit Description: SFR TD#15-38-44
Total Completed Inspections - 24
Date Description Inspector Results Comments
06/23/2005 PLUMBING - ROUGH, SOIL HPEDROZA Approved IVRS - Inspection :*
06/30/2005 ELECTRIC - UNDERGROUND HPEDROZA Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/01/2005 EXCAVATION/LAYOUT REBAR & ZON HPEDROZA Approved IVRS - Inspection :*
1) ITEM 2010 NOT REQUIRED PER PERMIT
07/01/2005 ELECTRIC - UFER HPEDROZA Approved IVRS - Inspection :*
07/01/2005 BUILDING PRE-SLAB HPEDROZA Approved IVRS - Inspection :*
07/01/2005 STEM WALL/RETAINING WALL HPEDROZA Approved IVRS - Inspection :*
09/15/2005 EXT METAL CLIPS/EXT SHEATHING CTREVILL Approved IVRS - Inspection :*
1) RETRO H.D. WEST WALL SHEER AND INTERIOR GARAGE SHEER
09/15/2005 ROOF NAILING CTREVILL Approved IVRS - Inspection :*
09/23/2005 ELECTRIC - TEMPORARY SERVICE HPEDROZA Approved IVRS - Inspection :*
09/23/2005 ELECTRIC - CABLE DROP HPEDROZA Approved IVRS - Inspection :*
09/26/2005 TEP CLEARANCE - AM JKOZUCH Approved
09/29/2005 PLUMBING - SEWER HCS CONNECT HPEDROZA Approved IVRS - Inspection :*
09/30/2005 FRAMING HPEDROZA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS LINE NOT COMPLETE
2) NO TEST ON DWV'S
3) NAIL PROTECT ELECTRIC 2ND FLOOR N/W BEDROOM AND MASTER BEDROOM
4) STOPPED INSPECTION
09/30/2005 U VALUE FOR WINDOW HPEDROZA Approved IVRS - Inspection :*
09/30/2005 STUCCO MESH HPEDROZA Approved IVRS - Inspection :*
09/30/2005 PLUMBING - GAS PRESSURE TEST HPEDROZA Approved IVRS - Inspection :
See detailed listing on site.| 999*
09/30/2005 MECHANICAL - INTERMEDIATE HPEDROZA Approved IVRS - Inspection :
See detailed listing on site.| 999*
09/30/2005 PLUMBING - INTERMEDIATE HPEDROZA Approved IVRS - Inspection :
See detailed listing on site.| 999*
09/30/2005 ELECTRIC - INTERMEDIATE HPEDROZA Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/09/2006 SHEET ROCK NAILING CTREVILL Approved IVRS - Inspection :*
05/16/2006 PLUMBING - FINAL CTREVILL Approved IVRS - Inspection :*
05/17/2006 MECHANICAL - FINAL CTREVILL Approved IVRS - Inspection :*
05/17/2006 ELECTRIC - FINAL CTREVILL Approved IVRS - Inspection :*
05/17/2006 BUILDING - FINAL CTREVILL Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW