Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Address NEW:
913 N DESERT AV #A
Apply Date:
05/24/2005
Applicant:
BRIGHT, RICK LANE
Description:
REMODEL:CONDO'S INTERIOR - FURR-OUT WOOD FRAMING W/ GYP BD - SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED - FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
Architects:
  • BRIGHT, RICK LANE

Permit Reviews

Permit Number - T05CM02360
Permit Status: Final
Permit Description: REMODEL:CONDO'S INTERIOR - FURR-OUT WOOD FRAMING W/ GYP BD - SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED - FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
Start Date Submittal Complete Date Status  
05/24/2005 COMMERCIAL TI 06/15/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM02360
Permit Status: Final
Permit Description: REMODEL:CONDO'S INTERIOR - FURR-OUT WOOD FRAMING W/ GYP BD - SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED - FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
Total Outstanding Activity Conditions - 1
Date Name
05/24/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM02360
Permit Description: REMODEL:CONDO'S INTERIOR - FURR-OUT WOOD FRAMING W/ GYP BD - SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED - FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
Total Completed Inspections - 12
Date Description Inspector Results Comments
04/11/2006 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
UNIT B - GAS OK
TUB DRAIN FITTING IS UPSIDE DOWN. PROVIDE TEST ON TUB OVERFLOW CONNECTION.
REPLACE BROKEN CLOSET FLANGE WITH A LISTED FLANGE. SECURE TO FLOOR.
UNIT C -- GAS OK
TEST TUB OVERFLOW. SILICONE IS NOT APPROVED FOR USE AT TUB OVERFLOW GASKET.
UNIT D -- GAS OK
COPPER TOUCHING BANG PLATE.
LAUNDRY TRAP ARM HAS BACKPITCH.
CLOSET FLANGE SHALL BE LISTED.
TUB DRAIN UPSIDE DOWN.
PROVIDE TEST ON OVERFLOW
T&P SHALL TERMINATE 6" ABOVE GROUND.
05/12/2006 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
CLOSET FLANGES OK
05/12/2006 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
12 PSI TEST FROM METER EXISTING TO BUILDING NOW TO WATER HEATER & FURNACE OK
05/22/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
OK FOR SHEETROCK
05/22/2006 FRAMING JBURGE Approved IVRS - Inspection :*
(UNIT A) OK TO SHEETROCK
05/22/2006 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
OK ROUGH
05/25/2006 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
UNIT "A" OK TO TAPE
07/21/2006 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection :*
07/25/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
07/25/2006 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
07/26/2006 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
07/27/2006 PERMIT FINALED BFLORES Approved