Permit: T05CM02360
Permit Details
Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
913 N DESERT AV #A
Address NEW:
913 N DESERT AV #A
Apply Date:
05/24/2005
Applicant:
BRIGHT, RICK LANE
Description:
REMODEL:CONDO'S INTERIOR - FURR-OUT WOOD FRAMING W/ GYP BD - SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED - FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
Architects:
- BRIGHT, RICK LANE
Permit Reviews
Permit Number - T05CM02360
Permit Status: Final
Permit Description: REMODEL:CONDO'S INTERIOR
- FURR-OUT WOOD FRAMING W/ GYP BD
- SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED
- FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/24/2005 | COMMERCIAL TI | 06/15/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02360
Permit Status: Final
Permit Description: REMODEL:CONDO'S INTERIOR
- FURR-OUT WOOD FRAMING W/ GYP BD
- SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED
- FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/24/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM02360
Permit Description: REMODEL:CONDO'S INTERIOR
- FURR-OUT WOOD FRAMING W/ GYP BD
- SMOKE DETECTORS ON EACH LEVEL INTERCONNECTED
- FOUR UNIT, 2 STORY WITH 3 BEDROOM UNITS
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2006 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* UNIT B - GAS OK TUB DRAIN FITTING IS UPSIDE DOWN. PROVIDE TEST ON TUB OVERFLOW CONNECTION. REPLACE BROKEN CLOSET FLANGE WITH A LISTED FLANGE. SECURE TO FLOOR. UNIT C -- GAS OK TEST TUB OVERFLOW. SILICONE IS NOT APPROVED FOR USE AT TUB OVERFLOW GASKET. UNIT D -- GAS OK COPPER TOUCHING BANG PLATE. LAUNDRY TRAP ARM HAS BACKPITCH. CLOSET FLANGE SHALL BE LISTED. TUB DRAIN UPSIDE DOWN. PROVIDE TEST ON OVERFLOW T&P SHALL TERMINATE 6" ABOVE GROUND. |
| 05/12/2006 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* CLOSET FLANGES OK |
| 05/12/2006 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 12 PSI TEST FROM METER EXISTING TO BUILDING NOW TO WATER HEATER & FURNACE OK |
| 05/22/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
| 05/22/2006 | FRAMING | JBURGE | Approved | IVRS - Inspection :* (UNIT A) OK TO SHEETROCK |
| 05/22/2006 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* OK ROUGH |
| 05/25/2006 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* UNIT "A" OK TO TAPE |
| 07/21/2006 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 07/25/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 07/25/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 07/26/2006 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 07/27/2006 | PERMIT FINALED | BFLORES | Approved |