Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Withdrwn
Type:
COMMERCIAL ALTERATION
Address NEW:
40 W FORT LOWELL RD
Apply Date:
05/13/2005
Applicant:
MEYER, JAMES CHAUNCEY
Description:
TI:CHARTER SCHOOL WOOD POSTS AND GLU-LAM BEAMS, METAL STUDS W/ GYP BD. REMODEL SCHOOL 104' x 50' SPACE ; OFFICE AREA 2050 SF W/O.L. = 20 AND CLASSROOM AREA OF 2950 SF W/ O.L. = 147. T.O.L. = 167. -CHECK SHEAR WALL AT WEST SIDE OF T.I. FOR CONFORMANCE W/ TWO-HOUR FIRE-RATED WALL PER 2003 IBC SECTION 7 TABLE 702.1(2) ITEM 3-1.4. - CHECK EXITS, EXIT SIGNAGE AND EMERGENCY LIGHTING FOR EXITING PER IBC SEC 10 AND 11.
Architects:
  • MEYER, JAMES CHAUNCEY

Permit Reviews

Permit Number - T05CM02189
Permit Status: Withdrwn
Permit Description: TI:CHARTER SCHOOL WOOD POSTS AND GLU-LAM BEAMS, METAL STUDS W/ GYP BD. REMODEL SCHOOL 104' x 50' SPACE ; OFFICE AREA 2050 SF W/O.L. = 20 AND CLASSROOM AREA OF 2950 SF W/ O.L. = 147. T.O.L. = 167. -CHECK SHEAR WALL AT WEST SIDE OF T.I. FOR CONFORMANCE W/ TWO-HOUR FIRE-RATED WALL PER 2003 IBC SECTION 7 TABLE 702.1(2) ITEM 3-1.4. - CHECK EXITS, EXIT SIGNAGE AND EMERGENCY LIGHTING FOR EXITING PER IBC SEC 10 AND 11.
Start Date Submittal Complete Date Status  
05/13/2005 PLANS OK TO SUBMIT - COMM 05/17/2005 COMPLETED Review Details
05/17/2005 COMMERCIAL TI 07/13/2005 COMPLETED Review Details
07/13/2005 RESUBMITTAL 09/08/2005 COMPLETED Review Details
09/15/2005 RESUBMITTAL 12/05/2005 STOPPED Review Details

Outstanding Activity Conditions

Permit Number - T05CM02189
Permit Status: Withdrwn
Permit Description: TI:CHARTER SCHOOL WOOD POSTS AND GLU-LAM BEAMS, METAL STUDS W/ GYP BD. REMODEL SCHOOL 104' x 50' SPACE ; OFFICE AREA 2050 SF W/O.L. = 20 AND CLASSROOM AREA OF 2950 SF W/ O.L. = 147. T.O.L. = 167. -CHECK SHEAR WALL AT WEST SIDE OF T.I. FOR CONFORMANCE W/ TWO-HOUR FIRE-RATED WALL PER 2003 IBC SECTION 7 TABLE 702.1(2) ITEM 3-1.4. - CHECK EXITS, EXIT SIGNAGE AND EMERGENCY LIGHTING FOR EXITING PER IBC SEC 10 AND 11.
Total Outstanding Activity Conditions - 2
Date Name
05/13/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
02/07/2006 FINAL ELEVATION CERTIFICATE REQUIRED: AN ORIGINAL FINAL ELEVATION CERTIFICATE SEALED BY A REGISTERED LAND SURVEYOR IS REQ'D. MAIL ELEVATION CERTIFICATE TO: CITY OF TUCSON, PLANNING & DEVELOPMENT SERVICES DEPT, ATTN: LOREN MAKUS, P.O. BOX 27210, TUCSON, AZ 85726-7210 OR DELIVER IT TO THE 1ST FL NORTH SIDE OF 201 N. STONE AVE. THIS CONDITION APPLIES TO ALL FINAL INSPECTIONS (1090, 2090, 3090, 4090) AND SHOULD NOT BE SCHEDULED UNTIL THE ELEVATION CERTIFICATE AND THE CONDITION HAVE BEEN APPROVED. LOREN'S IS 837-4927.

Outstanding Inspections

Permit Status: Withdrwn
Permit Number: T05CM02189
Permite Description: TI:CHARTER SCHOOL WOOD POSTS AND GLU-LAM BEAMS, METAL STUDS W/ GYP BD. REMODEL SCHOOL 104' x 50' SPACE ; OFFICE AREA 2050 SF W/O.L. = 20 AND CLASSROOM AREA OF 2950 SF W/ O.L. = 147. T.O.L. = 167. -CHECK SHEAR WALL AT WEST SIDE OF T.I. FOR CONFORMANCE W/ TWO-HOUR FIRE-RATED WALL PER 2003 IBC SECTION 7 TABLE 702.1(2) ITEM 3-1.4. - CHECK EXITS, EXIT SIGNAGE AND EMERGENCY LIGHTING FOR EXITING PER IBC SEC 10 AND 11.
Total Outstanding Inspections - 12
Last Inspection Date Description Inspector Results Comments
EXCAVATION/LAYOUT REBAR & ZON N/A Not Inspected
REINFORCED MASONRY PRE-GROUT N/A Not Inspected
FRAMING N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - INTERMEDIATE N/A Not Inspected
ELECTRIC - ABOVE CEILING N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
MECHANICAL - ABOVE CEILING N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
FIRE - ALARM FINAL N/A Not Inspected
FIRE - FINAL N/A Not Inspected