Permit: T05CM02010
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
10382 E CAMINO QUINCE
Address NEW:
10382 E CAMINO QUINCE
Apply Date:
05/05/2005
Applicant:
GALLAGHER CHARLES G & DEBORAH D CP/RS
Description:
ADDT TWO BEDROOMS & BATH
Outstanding Activity Conditions
Permit Number - T05CM02010
Permit Status: Final
Permit Description: ADDT TWO BEDROOMS & BATH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/05/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM02010
Permit Description: ADDT TWO BEDROOMS & BATH
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2005 | PLUMBING - ROUGH, SOIL | WNORTH | Approved | IVRS - Inspection :* |
| 06/24/2005 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |
| 06/24/2005 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | IVRS - Inspection :* |
| 06/27/2005 | ELECTRIC - SERVICE RELOCATION | WNORTH | Approved | IVRS - Inspection :* UFER GROUND APPROVED |
| 09/19/2005 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
| 09/19/2005 | EXT METAL CLIPS/EXT SHEATHING | WNORTH | Approved | IVRS - Inspection :* |
| 01/25/2006 | U VALUE FOR WINDOW | WNORTH | Approved | IVRS - Inspection :* |
| 05/31/2006 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 05/31/2006 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 05/31/2006 | FRAMING | WNORTH | Approved | IVRS - Inspection :* |
| 05/31/2006 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
| 06/01/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER W. NORTH |
| 06/17/2006 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 06/17/2006 | SHEET ROCK NAILING | WNORTH | Approved | IVRS - Inspection :* |
| 08/08/2006 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection :* 1) SMOKE DETECTOR CIRCUIT NEEDS TO BE ARC FAULT 2) NEED VACUUM BREAKER ON HOSE BIB 3) INTERIOR NOT COMPLETE |
| 08/08/2006 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 08/08/2006 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 08/08/2006 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 08/08/2006 | ELECTRIC - CABLE DROP | WNORTH | Approved | IVRS - Inspection :* |
| 08/07/2007 | PERMIT FINALED | BFLORES | Approved |