Permit: T05CM01631
Permit Details
Apply Date:
04/13/2005
Applicant:
JAY TRIPP
Description:
REPL WATER HEATER
Outstanding Activity Conditions
Permit Number - T05CM01631
Permit Status: Expired
Permit Description: REPL WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/13/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM01631
Permite Description: REPL WATER HEATER
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2005 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE WEATHER PROOF ENCLOSURE PER WATER HEATER. 2) SINGLE WALL VENT REQUIRES 6" CLEARANCE FROM COMBUSTIBLES. 3) PROVIDE ROOF FLASHING AT ROOF PENETRATION. 4) PROVIDE APPROVED CAP AT VENT FOR WATER HEATER. 5) PROVIDE 3-GALV SCREWS OR RIVETS AT EACH JOINT OF VENT PIPING |