Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Address NEW:
4660 E CAMP LOWELL DR
Apply Date:
03/14/2005
Applicant:
RIO WEST DEVELOPMENT AND CONSTRU
Description:
SHELL:NEW BLDG -RETAIL
Contractors:
  • RIO WEST DEVELOPMENT AND CONSTRU

Permit Reviews

Permit Number - T05CM01127
Permit Status: Final
Permit Description: SHELL:NEW BLDG -RETAIL
Start Date Submittal Complete Date Status  
03/14/2005 PLANS OK TO SUBMIT - 3RD PARTY 03/22/2005 COMPLETED Review Details
03/14/2005 PLANS OK TO SUBMIT - SITE 03/14/2005 COMPLETED Review Details
03/22/2005 3RD PARTY REVIEW-COMMERCIAL 05/26/2005 COMPLETED Review Details
03/22/2005 SITE 03/22/2005 COMPLETED Review Details
05/26/2005 POST 3RD PARTY REVIEW 05/27/2005 COMPLETED Review Details
10/07/2005 POST 3RD PARTY REVIEW 10/20/2005 COMPLETED Review Details
10/07/2005 REVISION - SITE 10/20/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM01127
Permit Status: Final
Permit Description: SHELL:NEW BLDG -RETAIL
Total Outstanding Activity Conditions - 1
Date Name
03/14/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM01127
Permit Description: SHELL:NEW BLDG -RETAIL
Total Completed Inspections - 34
Date Description Inspector Results Comments
08/18/2005 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection :*
1) OK 1-3/0 TO REBAR
09/06/2005 SITE - SEWER TRINIVJR Approved IVRS - Inspection :*
1) HCS CONNECTION AT PROPERTY LINE IS OK
2) 4" BLDG SEWER IS STUBBED INTO PAD AREA ONLY
3) OK TO BACKFILL TRENCH
4) NOTE: THIS INSPECTION IS FOR A-1 AND A-2
09/15/2005 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection :*
1) YARDWATER FROM BACKFLOW PREVENTER LOCATION TO BLDG SERVICE LOCATION IS OK
2) OK TO BACKFILL TRENCH
09/16/2005 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved Separate plans and permits required for underground fire sprinkler piping.
10/24/2005 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection :*SOIL WATER TEST IS OK.
HCS CONNECTION IS OK
THIS INSPECTION IS FOR THE GREASE . INTERCEPTOR CONNECTED TO HCS AND INLET STUB OUT OF INTERCEPTOR 3' UPSTREAM ONLY
OK TO BACKFILL THE TRENCH.
12/08/2005 EXCAVATION/LAYOUT REBAR & ZON JCAGLE Approved IVRS - Inspection :*
12/14/2005 STEM WALL/RETAINING WALL JCAGLE Approved IVRS - Inspection :*BUILDING A-2
02/10/2006 REINFORCED MASONRY PRE-GROUT JCAGLE Approved IVRS - Inspection :*
BUILDING A-2 LINES A/1-5-2 (16'8"-20'8"); 1/A.2-B, B/1-1.3 (17'4"-20' 8"); A.2/1.5-2 (18'-20'8")
04/05/2006 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
04/10/2006 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
OK PVC CONDUITS UNDER SLAB
04/17/2006 ROOF NAILING JBURGE Approved IVRS - Inspection :*
04/20/2006 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
05/18/2006 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
NEVER USE AIR TO TEST PVC
06/09/2006 STUCCO MESH JBURGE Approved IVRS - Inspection :*
06/13/2006 FRAMING JBURGE Approved IVRS - Inspection :*
01/11/2007 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
ENSURE THAT REBAR IS OFF THE GROUND
OK TO POUR SLAB
03/28/2007 PLUMBING - ROOF DRAINS BBENEDON Approved IVRS - Inspection :*
PROPERLY TERMINATE ROOF DRAIN FOR FINAL
03/28/2007 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection :*
03/28/2007 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
03/28/2007 ELECTRIC - OUTDOOR LIGHTING RHOLLAND Approved IVRS - Inspection :*
03/28/2007 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
03/28/2007 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
03/28/2007 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
03/28/2007 NPPO - FINAL ACONNOR Approved
03/28/2007 LANDSCAPE - FINAL ACONNOR Approved
03/28/2007 SIGN - FINAL JYBARRA Approved
03/28/2007 FIRE - FINAL LTHOMAS Approved
03/28/2007 FIRE SPKLR - FINAL LTHOMAS Approved
03/28/2007 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
03/28/2007 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
03/30/2007 ENGINEERING - FINAL JBRUCKME Approved
03/30/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
04/02/2007 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
04/04/2007 PERMIT FINALED BFLORES Approved