Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Address NEW:
2480 N SILVERBELL RD
Apply Date:
03/14/2005
Applicant:
ARCHITECTURAL DESIGN GROUP INC
Description:
SHELL BUILDING
Contractors:
  • CHESTNUT CONSTRUCTION CORPORATIO

Permit Reviews

Permit Number - T05CM01107
Permit Status: Final
Permit Description: SHELL BUILDING
Start Date Submittal Complete Date Status  
01/10/2006 3RD PARTY REVIEW-REVISION/OTHER 01/19/2006 COMPLETED Review Details
01/20/2006 3RD PARTY REVIEW-REVISION/OTHER 01/20/2006 COMPLETED Review Details
03/14/2005 PLANS OK TO SUBMIT - 3RD PARTY 03/16/2005 COMPLETED Review Details
03/16/2005 3RD PARTY REVIEW-COMMERCIAL 04/21/2005 COMPLETED Review Details
04/21/2005 POST 3RD PARTY REVIEW 04/28/2005 COMPLETED Review Details
04/28/2005 OTHER 04/28/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM01107
Permit Status: Final
Permit Description: SHELL BUILDING
Total Outstanding Activity Conditions - 1
Date Name
03/14/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM01107
Permit Description: SHELL BUILDING
Total Completed Inspections - 33
Date Description Inspector Results Comments
05/17/2005 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection :*
05/17/2005 EXCAVATION/LAYOUT REBAR & ZON HLEYVA Approved IVRS - Inspection :*
05/20/2005 STEM WALL/RETAINING WALL HLEYVA Approved IVRS - Inspection :*
05/24/2005 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1) CONNECTIONS AT 6" EXISTING OK
2) OK TO BACKFILL
05/25/2005 SITE - SEWER RMYERS Approved IVRS - Inspection :*
05/25/2005 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
05/26/2005 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
06/17/2005 REINFORCED MASONRY PRE-GROUT AMATHIES Approved IVRS - Inspection :*
06/22/2005 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :* 1) 1 1/4" SCH40 PVC YARDWATER FROM METER TO BLDG. OK CONTRACTOR TO REDLINE SITE PLAN.
07/05/2005 ELECTRIC - UNDERGROUND MCAPISTR Approved IVRS - Inspection :* PVC EXTENSION TO TEP T FMR.
07/21/2005 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
07/27/2005 FRAMING AQUIROZ Approved IVRS - Inspection :*
08/03/2005 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1) ABS DWV THRU ROOF OK
2) COPPER OK
3) GAS PIPING IN WALLS OK
4) OK TO COVER ALL AREAS
08/03/2005 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
08/04/2005 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
08/05/2005 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection :*
08/09/2005 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
08/09/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
08/25/2005 BUILDING ABOVE CEILING AMATHIES Approved IVRS - Inspection :*
APPROVED FOR SUITE #100
08/25/2005 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection :*
1) SUSPENDED ROUGH DUCT ONLY
08/25/2005 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 X 4 FIXTURES REQUIRE ALL 4 WINGS BENT OVER T-BAR
2) EXIT LIGHT AT FRONT MUST ALSO HAVE SEIMIC WIRE TO IT
3) TIE NEUTRAL TO UFER AT SERVICE
08/25/2005 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
08/25/2005 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :*
08/25/2005 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
08/25/2005 U VALUE FOR WINDOW AMATHIES Approved IVRS - Inspection :*
08/25/2005 STUCCO MESH AMATHIES Approved IVRS - Inspection :*
08/28/2005 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1) PLUMBING FINAL OK
2) OK FOR C OF O PENDING ANY OTHER INSPECTION
08/31/2005 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection :*
1) OK FOR C OF O UNIT #100 (SPACE IN SHELL)
2) SHELL NOT COMPLETE
08/31/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
OK TEMP C OF O SRC#100
08/31/2005 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :*
1) OK FOR TEMP C OF O UNIT #100
08/31/2005 FIRE - FINAL LTHOMAS Approved
02/06/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
02/10/2006 ENGINEERING - FINAL MRUSSO Approved

Documents

File Name Document Type  
None LETTER OF COMPLETION VIEW
None DOCUMENTS VIEW