Permit: T05CM01035
Permit Details
Apply Date:
03/08/2005
Applicant:
PULTE HOME CORPORATION ARIZONA *C
Description:
SFR: TD # 16-15-31
Contractors:
- PULTE HOME CORPORATION ARIZONA *C
Permit Reviews
Permit Number - T05CM01035
Permit Status: C of o
Permit Description: SFR: TD # 16-15-31
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/08/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 03/09/2005 | COMPLETED |
03/23/2005 | REVISION | 03/30/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM01035
Permit Status: C of o
Permit Description: SFR: TD # 16-15-31
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/08/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM01035
Permit Description: SFR: TD # 16-15-31
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/11/2005 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | |
04/11/2005 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | |
04/11/2005 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | APPROVED A 2ND TIME BECAUSE PLOT PLAN WAS REVISED, HOUSE WAS MOVED AND PLUMBING RE-DONE |
04/26/2005 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* |
04/26/2005 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
04/26/2005 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection :* |
05/16/2005 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection :* 1) SHIM ALL 3 PT BEARING TRUSSES INTERIOR 2) INSTALL LTT20 AT GARAGE INTERIOR 3) ARE 1ST TO 2ND FLOOR FLAT STRAPS REQUIRED OR NOT 4) 88A10-TRUSS TO LONG APPROX 6" |
05/16/2005 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
06/16/2005 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
06/16/2005 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
06/17/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
07/26/2005 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :*MISSING DAMPER 2ND. FLR. EXHAUST FAN |
07/26/2005 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection :* |
07/26/2005 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
07/26/2005 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
07/26/2005 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
07/26/2005 | FRAMING | RFREIDIN | Approved | IVRS - Inspection :* |
08/04/2005 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
08/04/2005 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection :* |
10/13/2005 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
10/13/2005 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
10/13/2005 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
10/13/2005 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
04/18/2006 | PERMIT FINALED | LJACKSON | Approved |