Permit: T05CM00233
Permit Details
Apply Date:
01/19/2005
Applicant:
K B HOME OF TUCSON *C
Description:
SFR TD#15-37-33
Contractors:
- K B HOME OF TUCSON *C
Permit Reviews
Permit Number - T05CM00233
Permit Status: Expired
Permit Description: SFR TD#15-37-33
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/19/2005 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 01/19/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM00233
Permit Status: Expired
Permit Description: SFR TD#15-37-33
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
01/19/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
01/19/2005 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM00233
Permite Description: SFR TD#15-37-33
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2005 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
06/22/2005 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM00233
Permit Description: SFR TD#15-37-33
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/22/2005 | PLUMBING - SEWER HCS CONNECT | FGREER | Approved | IVRS - Inspection :* |
02/22/2005 | PLUMBING - YARD WTR LINE/TEST | FGREER | Approved | IVRS - Inspection :* |
02/22/2005 | PLUMBING - ROUGH, SOIL | FGREER | Approved | IVRS - Inspection :* |
02/25/2005 | ELECTRIC - UNDERGROUND | FGREER | Approved | IVRS - Inspection :* |
02/25/2005 | ELECTRIC - UFER | FGREER | Approved | IVRS - Inspection :* |
02/25/2005 | BUILDING PRE-SLAB | FGREER | Approved | IVRS - Inspection :* |
02/25/2005 | STEM WALL/RETAINING WALL | FGREER | Approved | IVRS - Inspection :* |
02/25/2005 | EXCAVATION/LAYOUT REBAR & ZON | FGREER | Approved | IVRS - Inspection :* |
03/25/2005 | ROOF NAILING | EDURAZO | Approved | IVRS - Inspection :* |
04/13/2005 | ELECTRIC - TEMPORARY SERVICE | EDURAZO | Approved | IVRS - Inspection :* |
04/13/2005 | ELECTRIC - CABLE DROP | EDURAZO | Approved | IVRS - Inspection :* |
04/13/2005 | EXT METAL CLIPS/EXT SHEATHING | EDURAZO | Approved | IVRS - Inspection :* |
04/14/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
04/20/2005 | U VALUE FOR WINDOW | FGREER | Approved | IVRS - Inspection :* |
04/20/2005 | STUCCO MESH | FGREER | Approved | IVRS - Inspection :* |
04/22/2005 | PLUMBING - GAS PRESSURE TEST | FGREER | Approved | IVRS - Inspection :* |
04/22/2005 | MECHANICAL - INTERMEDIATE | FGREER | Approved | IVRS - Inspection :* |
04/22/2005 | PLUMBING - INTERMEDIATE | FGREER | Approved | IVRS - Inspection :* |
04/22/2005 | ELECTRIC - INTERMEDIATE | FGREER | Approved | IVRS - Inspection :* |
04/22/2005 | FRAMING | FGREER | Approved | IVRS - Inspection :* |
05/06/2005 | SHEET ROCK NAILING | FGREER | Approved | IVRS - Inspection :* |
06/22/2005 | BUILDING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
06/22/2005 | PLUMBING - FINAL | ROHAVER | Approved | IVRS - Inspection :* |
06/22/2005 | BUILDING - FINAL | FGREER | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS AT SITE |
06/22/2005 | PLUMBING - FINAL | FGREER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |