Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM00076
Permit Details
Status:
Expired
Type:
SINGLE FAMILY NEW
Address:
2523 S AZTEC POINT TR
Address NEW:
2523 S AZTEC POINT TR
Apply Date:
01/06/2005
Applicant:
MONTEREY HOMES CONSTRUCTION INC *C
Description:
SFR TD#15-96-86
Contractors:
- MONTEREY HOMES CONSTRUCTION INC *C
Permit Reviews
Permit Number - T05CM00076
Permit Status: Expired
Permit Description: SFR TD#15-96-86
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/06/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 01/11/2005 | COMPLETED |
| 06/09/2005 | REVISION | 06/09/2005 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T05CM00076
Permit Status: Expired
Permit Description: SFR TD#15-96-86
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 01/06/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 01/06/2005 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 01/06/2005 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
| 01/06/2005 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM00076
Permite Description: SFR TD#15-96-86
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PERMIT FINALED | N/A | Not Inspected |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM00076
Permit Description: SFR TD#15-96-86
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/16/2005 | PLUMBING - SEWER HCS CONNECT | WNORTH | Approved | IVRS - Inspection :* |
| 03/16/2005 | PLUMBING - YARD WTR LINE/TEST | WNORTH | Approved | IVRS - Inspection :* |
| 03/16/2005 | PLUMBING - ROUGH, SOIL | WNORTH | Approved | IVRS - Inspection :* |
| 03/29/2005 | ELECTRIC - UFER | WNORTH | Approved | IVRS - Inspection :* |
| 03/29/2005 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |
| 03/29/2005 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | IVRS - Inspection :* |
| 04/15/2005 | EXT METAL CLIPS/EXT SHEATHING | WNORTH | Approved | IVRS - Inspection :* 1) ADD SUPPORT UNDER GIRDER TRUSS FRO FRAME INSPECTION |
| 04/15/2005 | ELECTRIC - TEMPORARY SERVICE | WNORTH | Approved | IVRS - Inspection :* |
| 04/15/2005 | ELECTRIC - CABLE DROP | WNORTH | Approved | IVRS - Inspection :* |
| 04/15/2005 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
| 04/18/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 05/09/2005 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 05/09/2005 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
| 05/09/2005 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 05/09/2005 | U VALUE FOR WINDOW | WNORTH | Approved | IVRS - Inspection :* |
| 05/09/2005 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
| 05/10/2005 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 05/10/2005 | FRAMING | WNORTH | Approved | IVRS - Inspection :* |
| 05/18/2005 | SHEET ROCK NAILING | WNORTH | Approved | IVRS - Inspection :* 1) PURPOSE OF WIRE WEST SIDE KITCHEN 6' UP ? |
| 07/25/2005 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 07/26/2005 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 07/26/2005 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 07/26/2005 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection :* |