Permit: T04PL02120
Permit Details
Apply Date:
12/01/2004
Applicant:
TUCSON PLUMBING & HEATING INC *C
Description:
REPLACE:GAS LINE (APA)
Contractors:
- TUCSON PLUMBING & HEATING INC *C
Outstanding Activity Conditions
Permit Number - T04PL02120
Permit Status: Expired
Permit Description: REPLACE:GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/01/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04PL02120
Permite Description: REPLACE:GAS LINE (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/03/2004 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :*/ 1) PROVIDE BONDING OF BLDG GAS PIPING |
Completed Inspections
Permit Status: Expired
Permit Number: T04PL02120
Permit Description: REPLACE:GAS LINE (APA)
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/03/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :*/ 1) 12 PSI AIR TEST FROM METER NOW 1" OVERHEAD TO ROOF TOP UNIT, STOVE, WATER HEATER AND DRYER OK |