Permit: T04PL01481
Permit Details
Apply Date:
08/17/2004
Applicant:
ARIZONA PROFESSIONAL PLUMBING*T
Description:
REPLACE:GAS LINE (APA)
Contractors:
- ARIZONA PROFESSIONAL PLUMBING*T
Outstanding Activity Conditions
Permit Number - T04PL01481
Permit Status: Final
Permit Description: REPLACE:GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/17/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04PL01481
Permit Description: REPLACE:GAS LINE (APA)
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :*/APPROVED-CORRECTION MADE-GAS CARD AT METER 889-1888 |
| 08/19/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :*/ 1) PROVIDE UPPER AND LOWER COMBUSTION AIR FOR WATER HEATER 2) WATER HEATER TEMPERATURE AND PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT |
| 08/19/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :*/ 1) 15 PSI AIR TEST FROM NEW METER LOCATION TO ROOF TOP UNIT, WATER HEATER AND DRYER |
| 02/18/2005 | PERMIT FINALED | LJACKSON | Approved |