Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
748 S FRONT ROYAL DR
Apply Date:
02/26/2004
Applicant:
ARIZONA PLUMBING SERVICES, DBA SEARS,*C
Description:
REPLACE: WATER HEATER APA
Contractors:
  • ARIZONA PLUMBING SERVICES, DBA SEARS,*C

Outstanding Activity Conditions

Permit Number - T04PL00386
Permit Status: Expired
Permit Description: REPLACE: WATER HEATER APA
Total Outstanding Activity Conditions - 1
Date Name
02/26/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T04PL00386
Permite Description: REPLACE: WATER HEATER APA
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/24/2004 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection 0000*/ 1) VENT FROM WATER HEATER TO BE EXTENDED 3' ABOVE COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE 2) TEMPERATURE AND PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL ON SITE FOR ALTERNATE FORM OF T & P RELIEF WITH INSTALLATION

Documents

File Name Document Type  
None DOCUMENTS VIEW