Permit: T04PL00342
Permit Details
Apply Date:
02/23/2004
Applicant:
ROTO ROOTER SERVICE AND PLUMBING;*C
Description:
REPAIR: GASLINE APA
Contractors:
- ROTO ROOTER SERVICE AND PLUMBING;*C
Outstanding Activity Conditions
Permit Number - T04PL00342
Permit Status: Expired
Permit Description: REPAIR: GASLINE APA
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/23/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04PL00342
Permite Description: REPAIR: GASLINE APA
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/01/2004 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection 0000*/ 1) COMBUSTIBLE VENT WITHIN 10' OF COOLER INSTAKE TO BE 3' ABOVE 2) PROVIDE BONDING OF GAS SYSTEM 3) LEFT-RIGHT NIPPLE COUPLING SHALL BE USED IN PLACE OF UNION IN LINE PIPING 4) WATER HEATER TO BE ADDED TO PERMIT 5) WATER HEATER T & P TO GRAVITY DRAIN TO DAY LIGHT |