Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address:
375 S STONE AV
Apply Date:
11/15/2004
Applicant:
CHANCES
Description:
C OF O:RESTAURANT OK W/INSPECTIONS

Permit Reviews

Permit Number - T04OT02272
Permit Status: Expired
Permit Description: C OF O:RESTAURANT OK W/INSPECTIONS
Start Date Submittal Complete Date Status  
11/15/2004 C OF O 11/18/2004 COMPLETED Review Details

Outstanding Inspections

Permit Status: Expired
Permit Number: T04OT02272
Permite Description: C OF O:RESTAURANT OK W/INSPECTIONS
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
HEALTH DEPT - FINAL 724-7908 N/A Not Inspected
11/19/2004 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection :12" ADDRESS #'S REQUIRED TO BE VISIBLE FROM STONE
REMOVE LATCH TOP OF ENTRANCE DOORS. pLACE SIGN OVER DOOR
PROVIDE APPROVED EXIT OFF PATIO WITH PANIC HARDWARE
REMOVE DOUBLE KEYED DEAD BOLT @ KITCHEN EXIT REPLACE WITH THUMB ACTIVATED AND INSTALL LEVER HANDLE "NO KNOWLEDGE" HARDWARE
2ND EXIT OFF RESTAURANT FLOOR MAY NOT HAVE HASP ON DOOR
11/19/2004 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*/1)SINGLE LIGHT FIXTURE BY BAR NEEDS AN APPROVED J-BOX FOR WIRE MAKE UP 2)WALL LIGHTS OUTSIDE ENTRANCE NOT WIRED PER LISTING, SHOULD BE A J-BOX BEHIND FIXTURES FOR MAKE-UP. SUPPORT MC CABLE
11/19/2004 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*PROVIDE ONE INCH AIR BREAKS @ FLOOR SINKS
FIX SINK @ WAIT STATION
COFFEE MACHINE TO BE BACKFLOW PROTECTED
INSTALL CGA OR AGA TESTED GAS SHUT OFF @ WATER HEATER
BACKFLOW MAY BE REQUIRED @ MOP SINK BY WATER HEATER
11/19/2004 FIRE - FINAL N/A Denied 1.) Panic hardware required on secondary exits -
east exit door to patio and gate out of patio area to public way.
2.) Remove double cylinder keyed dead bolts from exit doors with panic hardware.
3.) Maintain proper coverage over appliances under hood system. Plans and permits needed for any changes to extinguishing system.
4.) Inspection needed for hood system every 6 months.
5.) Address numbers on building.
11/19/2004 SIGN - FINAL N/A Denied IVRS - Inspection :
The occupancy inspection reveals that corrections are required. Please furni

Completed Inspections

Permit Status: Expired
Permit Number: T04OT02272
Permit Description: C OF O:RESTAURANT OK W/INSPECTIONS
Total Completed Inspections - 1
Date Description Inspector Results Comments
11/19/2004 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*/RATED 1 HR CHASE TOP OF GOOD TO EXHAUST BLOWER?? 2)16 GA. BLK. IRON EXHAUST DUCT? 3)ROOF TOP EXHAUST BLOWERS, NOT GREASE/VAPAR REST. RATED!! 4)EXISTING RESTAURANT KITCHEN EXIST. UVAC EQUIP, NO NEW EQUIP

Documents

File Name Document Type  
None CONSTRPLANS VIEW