Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
5801 E 26TH ST
Address NEW:
5801 E 26TH ST
Apply Date:
09/15/2004
Applicant:
DAVID SANDY
Description:
ELECTRIC SERVICE UPGRADE: 70 AMP TO 100 AMP

Permit Reviews

Permit Number - T04EL01903
Permit Status: Expired
Permit Description: ELECTRIC SERVICE UPGRADE: 70 AMP TO 100 AMP
Start Date Submittal Complete Date Status  
09/15/2004 ELECTRICAL 09/15/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04EL01903
Permit Status: Expired
Permit Description: ELECTRIC SERVICE UPGRADE: 70 AMP TO 100 AMP
Total Outstanding Activity Conditions - 1
Date Name
09/15/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T04EL01903
Permite Description: ELECTRIC SERVICE UPGRADE: 70 AMP TO 100 AMP
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/06/2004 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Completed Inspections

Permit Status: Expired
Permit Number: T04EL01903
Permit Description: ELECTRIC SERVICE UPGRADE: 70 AMP TO 100 AMP
Total Completed Inspections - 4
Date Description Inspector Results Comments
10/06/2004 ELECTRIC - SERVICE UPGRADE JORTA Approved IVRS - Inspection :
The service is not per code.| 210*/ 1) GAS METER IN FRONT OF SERVICE, VIOLATES 110.26 2) NEED ADDRESS TAG-CITY APPROVED 3) CONDUIT CROOKED
10/06/2004 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection :
See detailed listing on site.| 999*
10/06/2004 ELECTRIC - UNDERGROUND JORTA Approved IVRS - Inspection :
See detailed listing on site.| 999*
08/22/2005 TEP CLEARANCE - AM HLEYVA Approved INC CLEARED BY SUBA

Documents

File Name Document Type  
None DOCUMENTS VIEW