Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
6100 E BROADWAY BL
Apply Date:
12/30/2004
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI:BODY SHOP
Architects:
  • ACORN, KIM BRIAN
Contractors:
  • DIVISION II CONSTRUCTION COMPANY

Permit Reviews

Permit Number - T04CM05619
Permit Status: C of o
Permit Description: TI:BODY SHOP
Start Date Submittal Complete Date Status  
01/26/2005 3RD PARTY REVIEW-COMMERCIAL TI 03/01/2005 COMPLETED Review Details
03/01/2005 POST 3RD PARTY REVIEW 03/22/2005 COMPLETED Review Details
03/22/2005 POST 3RD PARTY REVIEW 04/05/2005 COMPLETED Review Details
07/27/2005 3RD PARTY REVIEW-REVISION/OTHER 08/08/2005 COMPLETED Review Details
08/23/2005 3RD PARTY REVIEW-REVISION/OTHER 08/30/2005 COMPLETED Review Details
10/04/2005 3RD PARTY REVIEW-REVISION/OTHER 10/06/2005 COMPLETED Review Details
12/30/2004 PLANS OK TO SUBMIT - 3RD PARTY 01/26/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM05619
Permit Status: C of o
Permit Description: TI:BODY SHOP
Total Outstanding Activity Conditions - 1
Date Name
12/30/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM05619
Permit Description: TI:BODY SHOP
Total Completed Inspections - 28
Date Description Inspector Results Comments
07/13/2005 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :* DO NOT POUR UNTIL PLUMBING APPROVED
07/13/2005 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
07/13/2005 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
07/28/2005 FRAMING LHANLY Approved IVRS - Inspection :*
07/28/2005 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection :*
08/01/2005 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
1) CLOSET FLANGES OK
2) H20 PIPING OK
08/01/2005 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*
08/01/2005 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
08/01/2005 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
08/04/2005 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
08/16/2005 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
08/17/2005 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
1) 30 PSI TEST FROM NEW VALVE LOCATION ON 3/4" TO RELOCATED HANGING SPACE HEATER OK
2) VENT FROM HEATER TO RUN IN UPWARD DIRECTION TO TERMINATION THRU ROOF
3) VENT CONNECTION FROM APPLIANCE TO FLUE PIPING TO BE APPROVED TRANSITION
09/01/2005 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) ON FINAL IDENTIFY A/C EQUIPMENT
2) MARK UNIT DATA PLATE WITH PROPER HEAT STRIP INSTALLED AN FUSE ACCORDINGLY
3) RELOCATE SUPPLY DIFFUSER IN BREAKROOM
4) DISCHARGE LINE ON MINI SPLIT SYSTEM IS CONDENSATING AND DRIPPING WATER
5) WILL CHECK CORRECTIONS ON FINAL
6) OK FOR CEILING TILES
7) VENT ON FURNACE CANNOT BE GREATER THAN 60 DEGREE AND HORIZONTAL SECTION CANNOT BE GREATER TAHN 75 PERCENT OF TOTAL HEIGHT
09/01/2005 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*
09/01/2005 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
09/01/2005 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection :*
09/09/2005 PLUMBING - YARD WTR LINE/TEST RRICH Approved
09/09/2005 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
09/09/2005 ELECTRIC - CONSTRUCTION POWER RSUBA Approved IVRS - Inspection :*
09/09/2005 ELECTRIC - SERVICE UPGRADE RSUBA Approved IVRS - Inspection :*
09/09/2005 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :*
09/12/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
1) OK FOR FINAL C OF O
09/14/2005 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
09/14/2005 FIRE - FINAL LTHOMAS Approved
09/14/2005 FIRE SPKLR - FINAL LTHOMAS Approved
09/15/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :* TEMP C/O; MUST PERMIT OR REMOVE MURAL SIGNS ON WEST ELEV
09/15/2005 RIGHT OF WAY - FINAL NKALAHAR Approved PER EMAIL
09/16/2005 ENGINEERING - FINAL DROBERTS Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
COFO_05-26-2006.TIF CERT OF OCC VIEW