Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
757 N LEUTEA DR
Address NEW:
757 N LEUTEA DR
Apply Date:
12/29/2004
Applicant:
JOSEPH SMITH
Description:
SFR:NEW
Contractors:
  • GOLDEN STAR PROPERTIES INC

Outstanding Activity Conditions

Permit Number - T04CM05605
Permit Status: Final
Permit Description: SFR:NEW
Total Outstanding Activity Conditions - 1
Date Name
12/29/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM05605
Permit Description: SFR:NEW
Total Completed Inspections - 24
Date Description Inspector Results Comments
10/28/2005 PLUMBING - ROUGH, SOIL ROHAVER Approved IVRS - Inspection :*
1) CAULK PIPES AT LOWER WEST SIDE
2) FINISH MESH AT ROOF STAIRWAY
11/15/2005 ELECTRIC - UNDERGROUND ROHAVER Approved IVRS - Inspection :*
11/15/2005 ELECTRIC - UFER ROHAVER Approved IVRS - Inspection :*
11/15/2005 BUILDING PRE-SLAB ROHAVER Approved IVRS - Inspection :*
11/15/2005 EXCAVATION/LAYOUT REBAR & ZON ROHAVER Approved IVRS - Inspection :*
12/22/2005 EXT METAL CLIPS/EXT SHEATHING WNORTH Approved IVRS - Inspection :*
1) AT FRAME INSPECTION, RETRO FIT PA STRAPS SPAULED OUT. 4 AT FRONT OF GARAGE AND FOUR ON WALL WEST OF GARAGE
2) STRAPS ON NORTH SIDE OK
3) RECOMMEND H2.5'S ON LEDGER IN LAUNDRY ROOM
12/22/2005 ROOF NAILING WNORTH Approved IVRS - Inspection :*
01/20/2006 U VALUE FOR WINDOW FVALENCI Approved IVRS - Inspection :*
01/25/2006 PLUMBING - GAS PRESSURE TEST DQUINN Approved
01/25/2006 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
01/25/2006 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
01/25/2006 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
01/25/2006 FRAMING DQUINN Approved IVRS - Inspection :*
02/08/2006 SHEET ROCK NAILING DQUINN Approved IVRS - Inspection :*
02/17/2006 STUCCO MESH DQUINN Approved IVRS - Inspection :*
02/28/2006 PLUMBING - YARD WTR LINE/TEST DQUINN Approved IVRS - Inspection :*
03/02/2006 PLUMBING - SEWER HCS CONNECT DQUINN Approved IVRS - Inspection :*
03/15/2006 ELECTRIC - TEMPORARY SERVICE ROHAVER Approved IVRS - Inspection :*
03/15/2006 ELECTRIC - CABLE DROP ROHAVER Approved IVRS - Inspection :*
03/17/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. O'HAVER
07/12/2006 MECHANICAL - FINAL ROHAVER Approved IVRS - Inspection :*
07/12/2006 PLUMBING - FINAL ROHAVER Approved IVRS - Inspection :*
07/12/2006 ELECTRIC - FINAL ROHAVER Approved IVRS - Inspection :*
07/27/2006 BUILDING - FINAL ROHAVER Approved IVRS - Inspection :*