Permit: T04CM05475
Permit Details
Apply Date:
12/17/2004
Applicant:
N/A
Description:
COVERED PARKING ADDITION TO FACTORY BUILDING: ADDITION FOR COVERED PARKING ,MASONRY FIREWALL,RETAINING WALL AND FENCE; - 172'3" x 39'8" STEEL PARKING CANOPY : STEEL ROOF DECKING, STEEL FRAMING W/ CABLE BRACING. - 17'4" HIGH REINFORCED MASONRY WALL x 51'4" LONG, ONE-HOUR FIRE-RATED WALL . - 3'6" REINFORCED MASONRY RETAINING WALL x 193.79' LONG - 10'0" HIGH CHAINLINK FENCE x 243'7 3/4" LONG. REVISION-APPROVED (2/7/05) : Structural steel.
Contractors:
- CANYON BUILDING AND DESIGN L L C
Permit Reviews
Permit Number - T04CM05475
Permit Status: Final
Permit Description: COVERED PARKING ADDITION TO FACTORY BUILDING:
ADDITION FOR COVERED PARKING ,MASONRY FIREWALL,RETAINING WALL AND FENCE;
- 172'3" x 39'8" STEEL PARKING CANOPY : STEEL ROOF DECKING, STEEL FRAMING W/ CABLE BRACING.
- 17'4" HIGH REINFORCED MASONRY WALL x 51'4" LONG, ONE-HOUR FIRE-RATED WALL .
- 3'6" REINFORCED MASONRY RETAINING WALL x 193.79' LONG
- 10'0" HIGH CHAINLINK FENCE x 243'7 3/4" LONG.
REVISION-APPROVED (2/7/05) : Structural steel.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/19/2005 | REVISION | 04/21/2005 | COMPLETED |
| 09/21/2004 | OTHER | 12/20/2004 | COMPLETED |
| 12/20/2004 | RESUBMITTAL | 12/22/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM05475
Permit Status: Final
Permit Description: COVERED PARKING ADDITION TO FACTORY BUILDING:
ADDITION FOR COVERED PARKING ,MASONRY FIREWALL,RETAINING WALL AND FENCE;
- 172'3" x 39'8" STEEL PARKING CANOPY : STEEL ROOF DECKING, STEEL FRAMING W/ CABLE BRACING.
- 17'4" HIGH REINFORCED MASONRY WALL x 51'4" LONG, ONE-HOUR FIRE-RATED WALL .
- 3'6" REINFORCED MASONRY RETAINING WALL x 193.79' LONG
- 10'0" HIGH CHAINLINK FENCE x 243'7 3/4" LONG.
REVISION-APPROVED (2/7/05) : Structural steel.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/17/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04CM05475
Permit Description: COVERED PARKING ADDITION TO FACTORY BUILDING:
ADDITION FOR COVERED PARKING ,MASONRY FIREWALL,RETAINING WALL AND FENCE;
- 172'3" x 39'8" STEEL PARKING CANOPY : STEEL ROOF DECKING, STEEL FRAMING W/ CABLE BRACING.
- 17'4" HIGH REINFORCED MASONRY WALL x 51'4" LONG, ONE-HOUR FIRE-RATED WALL .
- 3'6" REINFORCED MASONRY RETAINING WALL x 193.79' LONG
- 10'0" HIGH CHAINLINK FENCE x 243'7 3/4" LONG.
REVISION-APPROVED (2/7/05) : Structural steel.
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/19/2005 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection :* |
| 01/19/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
| 03/16/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :*APPROVED |
| 03/16/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 03/16/2005 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection :* |
| 03/18/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 03/18/2005 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 03/23/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* APPROVED |
| 03/30/2005 | PERMIT FINALED | BGRANT | Approved |