Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
2841 W CALLE GARDENIAS
Apply Date:
12/07/2004
Applicant:
CORRALES WILLIAM L & ROSIE JT/RS
Description:
ENCLOSURE:PORCH TO FAMILY ROOM & ADD PORCH AT REAR

Permit Reviews

Permit Number - T04CM05301
Permit Status: Final
Permit Description: ENCLOSURE:PORCH TO FAMILY ROOM & ADD PORCH AT REAR
Start Date Submittal Complete Date Status  
01/25/2005 REVISION - WALK THRU 01/25/2005 COMPLETED Review Details
08/05/2005 REVISION 08/08/2005 STOPPED Review Details
11/08/2005 REVISION - WALK THRU 11/08/2005 COMPLETED Review Details
12/07/2004 RESIDENTIAL BLDG/ZONING/ENGINE 12/07/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM05301
Permit Status: Final
Permit Description: ENCLOSURE:PORCH TO FAMILY ROOM & ADD PORCH AT REAR
Total Outstanding Activity Conditions - 1
Date Name
12/07/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM05301
Permit Description: ENCLOSURE:PORCH TO FAMILY ROOM & ADD PORCH AT REAR
Total Completed Inspections - 11
Date Description Inspector Results Comments
01/28/2005 EXCAVATION/LAYOUT REBAR & ZON ROHAVER Approved IVRS - Inspection :*A
01/28/2005 BUILDING PRE-SLAB ROHAVER Approved IVRS - Inspection :*
09/15/2005 ROOF NAILING ROHAVER Approved IVRS - Inspection :*
11/16/2005 FRAMING ROHAVER Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) EAST PORCH INSTALL LAG BOLTS 16" SPACING LEDGER INTO EXISTING STUDS BEHIND SIDIN (3/8" X 4 1/2" EACH STUD)
2) FRENCH DOORS NOT INSTALLED YET (3 LOCATIONS)
3) EXISTING WINDOWS NOT DEMO'D AND FILLED IN
4) 2 X 12 NAILER (SOUTH PORCH ROOF) TO BE LAGGED INTO EXISTING TRUSSES (1/2" DIAMETER X 6" LONG BOLTS)
5) INSTALL SIMPSON L50 EACH SIDE PRCH RAFTERS TO 2 X 12 NAILER
6) STOPPED INSPECTION
7) COMPLETE ALL AND RECALL
10/31/2006 ELECTRIC - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
01/04/2007 SHEET ROCK NAILING ROHAVER Approved IVRS - Inspection :*
01/04/2007 MECHANICAL - INTERMEDIATE ROHAVER Approved IVRS - Inspection :*
04/30/2007 MECHANICAL - FINAL JRIVA Approved IVRS - Inspection :*
04/30/2007 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection :*
04/30/2007 BUILDING - FINAL JRIVA Approved IVRS - Inspection :*
05/01/2007 PERMIT FINALED JWEATHER Approved