Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T04CM05213
Permit Details
Apply Date:
11/30/2004
Applicant:
K B HOME OF TUCSON *C
Description:
SFR TD#16-01-46
Contractors:
- K B HOME OF TUCSON *C
Permit Reviews
Permit Number - T04CM05213
Permit Status: C of o
Permit Description: SFR TD#16-01-46
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/30/2004 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 12/06/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM05213
Permit Status: C of o
Permit Description: SFR TD#16-01-46
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/30/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM05213
Permit Description: SFR TD#16-01-46
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2005 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | IVRS - Inspection :* |
| 01/27/2005 | ELECTRIC - UNDERGROUND | DQUINN | Approved | IVRS - Inspection :* NA |
| 01/27/2005 | ELECTRIC - UFER | DQUINN | Approved | IVRS - Inspection :* |
| 01/27/2005 | BUILDING PRE-SLAB | DQUINN | Approved | IVRS - Inspection :* |
| 01/27/2005 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | IVRS - Inspection :* |
| 03/09/2005 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 03/14/2005 | ELECTRIC - TEMPORARY SERVICE | DQUINN | Approved | IVRS - Inspection :* 1,2,3 NOT DONE-CAN CHECK AT INTERMEDIATE. CLEAR ECO |
| 03/14/2005 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection :* |
| 03/15/2005 | PLUMBING - SEWER HCS CONNECT | DQUINN | Approved | IVRS - Inspection :* |
| 03/15/2005 | TEP CLEARANCE - AM | HLEYVA | Approved | ECO |
| 04/12/2005 | FRAMING | DQUINN | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) ROCK WINDOW NOT DONE 2) NEED RED HEAD ON WEST GARAGE WALL 3) SHIM HEADERS WHERE NEEDED 4) FIREBLOCK SOUTH BED CHASE-1ST FLOOR 5) RE-INSTALL LOFT CAN LIGHT 6) INSULATE TUB HOLES |
| 04/12/2005 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 04/12/2005 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 04/12/2005 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |
| 04/12/2005 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 04/12/2005 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 04/12/2005 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 04/12/2005 | U VALUE FOR WINDOW | DQUINN | Approved | IVRS - Inspection :* |
| 04/15/2005 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection :* |
| 04/20/2005 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection :* |
| 05/03/2005 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 06/13/2005 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 06/13/2005 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 06/14/2005 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* 1) NO GAS |
| 06/14/2005 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 12/13/2005 | PERMIT FINALED | LJACKSON | Approved |