Permit: T04CM05055
Permit Details
Status:
Final
Type:
DUPLEX NEW
Address:
2557 N CROW CREEK LN #01
Address NEW:
2557 N CROW CREEK LN #01
Apply Date:
11/17/2004
Applicant:
KIPPES CONSTRUCTION L L C
Description:
DUPLEX TD#15-88-95
Contractors:
- KIPPES CONSTRUCTION L L C
Permit Reviews
Permit Number - T04CM05055
Permit Status: Final
Permit Description: DUPLEX TD#15-88-95
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/17/2004 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/17/2004 | COMPLETED |
| 11/17/2004 | RESIDENTIAL BLDG/ZONING/NPPO | 11/23/2004 | COMPLETED |
| 11/30/2004 | RESUBMITTAL | 12/23/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM05055
Permit Status: Final
Permit Description: DUPLEX TD#15-88-95
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/17/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04CM05055
Permit Description: DUPLEX TD#15-88-95
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2005 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection :* |
| 01/20/2005 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* OK #4 TO REBAR IN BOTTOM 3" OF FOOTING |
| 03/09/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* APPROVED |
| 03/09/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
| 03/28/2005 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection :* |
| 03/28/2005 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection :* |
| 04/19/2005 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
| 04/20/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 04/21/2005 | FRAMING | BSTEVENS | Approved | IVRS - Inspection :* 1) PENDING PLB APPROVAL |
| 04/25/2005 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection :* |
| 04/25/2005 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection :* |
| 06/17/2005 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection :* |
| 06/17/2005 | U VALUE FOR WINDOW | HLEYVA | Approved | IVRS - Inspection :* |
| 06/17/2005 | STUCCO MESH | HLEYVA | Approved | IVRS - Inspection :* |
| 07/06/2005 | ELECTRIC - CABLE DROP | RSUBA | Approved | IVRS - Inspection :* CEC |
| 08/22/2005 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* |
| 09/15/2005 | TEP CLEARANCE - AM | FGREER | Approved | ECO CLEARED BY HOLLANDER FOR UNITS #1 AND #2 |
| 09/15/2005 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :* |
| 10/03/2005 | ELECTRIC - FINAL | DSANTACR | Approved | |
| 10/03/2005 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
| 10/06/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :**OK FOR FINAL |
| 10/07/2005 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | |
| 10/07/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :*PLBG FINAL IS OK OK FOR C OF O |
| 10/10/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 02/07/2006 | PERMIT FINALED | JWEATHER | Approved |