Permit: T04CM04925
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1847 W SAN JUAN TR
Address NEW:
1847 W SAN JUAN TR
Apply Date:
11/09/2004
Applicant:
MOUNT CALVARY BAPTIST CHURCH
Description:
RECONNECT:ELECTRIC AND GAS
Outstanding Activity Conditions
Permit Number - T04CM04925
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC AND GAS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/09/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04CM04925
Permite Description: RECONNECT:ELECTRIC AND GAS
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/12/2004 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)PROVIDE 10 PSI MINIMUM AIR TEST AT TIME OF INSPECTION 2)SECURE WATER HEATER VENT PROPERLY. 3)PROVIDE AGA OR CSA GAS VALVE AT STOVE, FLEX MAY NOT PASS THRU CABINET WALL TO STOVE. |
| 11/12/2004 | PLUMBING - GAS PRESS TEST FNL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/12/2004 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T04CM04925
Permit Description: RECONNECT:ELECTRIC AND GAS
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/12/2004 | TEP CLEARANCE - PM | DHERRON | Approved | RECON PER RAY MAJUTA VIA PHONE |
| 11/19/2004 | ELECTRIC - FINAL | RMAJUTA | Approved | |
| 11/19/2004 | ELECTRIC - RECONNECT | RMAJUTA | Approved |