Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
5055 E BROADWAY BL D
Apply Date:
11/03/2004
Applicant:
N/A
Description:
TI:OFFICE
Contractors:
  • BARKER CONTRACTING INC

Permit Reviews

Permit Number - T04CM04852
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
02/03/2005 REVISION - WALK THRU 02/03/2005 COMPLETED Review Details
02/16/2005 REVISION 02/16/2005 COMPLETED Review Details
11/03/2004 COMMERCIAL TI 12/13/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM04852
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
11/03/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM04852
Permit Description: TI:OFFICE
Total Completed Inspections - 15
Date Description Inspector Results Comments
12/07/2004 FRAMING HLEYVA Approved IVRS - Inspection :*
1) SEE PLAN AT DEMISING WALL 3/A-2 MUST GO TO METAL DECK
2) CLARIFY-CHANGE PLANS TO REFLECT-TO SHEET ROCK
12/07/2004 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
1) OK TO COVER WALLS IN NURSING AND STAFFING AREAS
12/09/2004 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection :*
12/20/2004 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :
See detailed listing on site.| 999*/PVC CONDENSATE DRAIN NOT ALLOWED IN A PLENUM CEILING. STRAP FLEX DUCT UP OFF OF GRID & TILES. PROVIDE RETURN AIR GRILLS. BLANK OFF UNUSED SUPPLY OUTLET.
12/21/2004 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*/WILLL CHECK COPPER CONDENSATE DRAIN ON FINAL
12/21/2004 BUILDING - FINAL HLEYVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL TRADES TO BE APPROVED PRIOR TO BLDG FINAL
12/21/2004 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*/1)SECURELY ATTACH FIXTURES TO GRID - IF USING MANUFACTURES CLIPS THEY MUST BE EFFECTIVE - IF SCREWS 4 ON CORNERS OR 2 ON CENTER 2)FINISH INSTALLING VDV CABLES PER 725.6 & 800.6 3)SUPPORT FLEX CONDUIT AS PER CODE
02/10/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :* OK FOR FINAL
02/11/2005 ENGINEERING - FINAL DROBERTS Approved
02/11/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
02/11/2005 FIRE - FINAL LTHOMAS Approved
02/11/2005 RIGHT OF WAY - FINAL PWHIDDON Approved
02/15/2005 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection :* FINAL OK STOI
02/18/2005 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :* OK FINAL
02/22/2005 PLUMBING - INTERMEDIATE JSTANLEY Approved