Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address NEW:
544 N CONSTITUTION DR
Apply Date:
11/03/2004
Applicant:
KATHRYN HOLDEN
Description:
ALTERATION:DETACHED SHOP TO LIVING QUARTERS

Permit Reviews

Permit Number - T04CM04851
Permit Status: Final
Permit Description: ALTERATION:DETACHED SHOP TO LIVING QUARTERS
Start Date Submittal Complete Date Status  
11/03/2004 RESIDENTIAL BLDG/ZONING-WALKTHRU 11/03/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM04851
Permit Status: Final
Permit Description: ALTERATION:DETACHED SHOP TO LIVING QUARTERS
Total Outstanding Activity Conditions - 1
Date Name
11/03/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM04851
Permit Description: ALTERATION:DETACHED SHOP TO LIVING QUARTERS
Total Completed Inspections - 15
Date Description Inspector Results Comments
12/28/2004 FRAMING WNORTH Approved IVRS - Inspection :*
1) OK TO POUR WALL FOOTING
2) NEED OPENING FRAMED FOR HEAT PUMP (#7)
3) INSTALL CRIPPLES OVER HEADER ON SOUTH WALL
4) ADD HEADER (2-2 X 6'S) OVER WINDOW ON NORTH WALL
5) FRAME FOR SCREENED GABLE VENTS (#8)
12/28/2004 EXCAVATION/LAYOUT REBAR & ZON WNORTH Approved IVRS - Inspection :*
01/05/2005 STEM WALL/RETAINING WALL WNORTH Approved IVRS - Inspection :*
1) FRAMING OK WILL BE APPROVED WITH INTERMEDIATE INSPECTIONS AND NEW SIDING
01/06/2005 PLUMBING - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
01/06/2005 PLUMBING - YARD WTR LINE/TEST WNORTH Approved IVRS - Inspection :*
01/06/2005 PLUMBING - ROUGH, SOIL WNORTH Approved IVRS - Inspection :*
01/11/2005 MECHANICAL - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
01/11/2005 ELECTRIC - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
02/10/2005 SHEET ROCK NAILING WNORTH Approved IVRS - Inspection :*
02/10/2005 U VALUE FOR WINDOW WNORTH Approved IVRS - Inspection :*
04/26/2005 BUILDING - FINAL WNORTH Approved IVRS - Inspection :*
04/26/2005 MECHANICAL - FINAL WNORTH Approved IVRS - Inspection :*
04/26/2005 PLUMBING - FINAL WNORTH Approved IVRS - Inspection :*
04/26/2005 ELECTRIC - FINAL WNORTH Approved IVRS - Inspection :*
04/27/2005 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW