Permit: T04CM04757
Permit Details
Apply Date:
10/27/2004
Applicant:
METRO PERMIT EXPRESS, INC
Description:
TI:CAFETERIA & KITCHEN
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Permit Reviews
Permit Number - T04CM04757
Permit Status: C of o
Permit Description: TI:CAFETERIA & KITCHEN
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/27/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 10/28/2004 | COMPLETED |
10/28/2004 | 3RD PARTY REVIEW-COMMERCIAL | 12/02/2004 | COMPLETED |
12/09/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 12/15/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM04757
Permit Status: C of o
Permit Description: TI:CAFETERIA & KITCHEN
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/27/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM04757
Permit Description: TI:CAFETERIA & KITCHEN
Total Completed Inspections - 20
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2004 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)P.O.C. OF NEW BLDG DRAIN TO EXSISTING BLDG DRAIN IS OK 3)OK TO BACKFILL TRENCH |
12/28/2004 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK FOR RELOCATED HAND SINK. OVERHEAD WATER DISTRIBUTION IS OK 2) GAS PRESSURE TEST IS OK FOR ADDED STEAM KETTLE 3)OASSIS SINK IS OK |
12/28/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :*/SECURE APPROVED DRAWING SHOWING A FIRE WRAPPED DUCT CONNECTIOIN TO A RIDGID FIRE RATED CHASE. |
12/28/2004 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection :* |
12/29/2004 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | CLEAR |
12/29/2004 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
12/29/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
12/29/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
12/29/2004 | ENGINEERING - FINAL | JSALINE | Approved | C OF O APPROVED. |
12/29/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
12/30/2004 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection :* OK SUBJECT TO LISTING APPROVAL |
12/30/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* OK TEMP C OF O |
12/30/2004 | FIRE - FINAL | LTHOMAS | Approved | |
12/30/2004 | ELECTRIC - ABOVE CEILING | RSUBA | Approved | IVRS - Inspection :* |
12/30/2004 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :* |
12/31/2004 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :*1) OK FOR TEMP C OF O |
01/04/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :*THIS IS A TYPE II HOOD, FIRE WRAPED 16 GA. DUCT ( EXHAUST) DOWN TO TOP OF HOOD. |
01/04/2005 | MECHANICAL - HOODS | CWILLIAM | Approved | IVRS - Inspection :* |
01/04/2005 | MECHANICAL - HOODS | CWILLIAM | Approved | IVRS - Inspection :*HOOD 16 GA DUET, 3M FIRE?? PROGRESSING |
01/07/2005 | HEALTH DEPT - FINAL 724-7908 | SBROWNIN | Approved |