Permit: T04CM04379
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
7191 E BROADWAY BL
Address NEW:
7191 E BROADWAY BL
Apply Date:
09/30/2004
Applicant:
METRO PERMIT EXPRESS
Description:
TI:RETAIL
Contractors:
- S K BUILDERS INC
Permit Reviews
Permit Number - T04CM04379
Permit Status: C of o
Permit Description: TI:RETAIL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/30/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 10/05/2004 | COMPLETED |
| 10/05/2004 | 3RD PARTY REVIEW-COMMERCIAL TI | 11/04/2004 | COMPLETED |
| 11/04/2004 | POST 3RD PARTY REVIEW | 11/17/2004 | COMPLETED |
| 11/17/2004 | RESUBMITTAL | 11/17/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM04379
Permit Status: C of o
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/30/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM04379
Permit Description: TI:RETAIL
Total Completed Inspections - 31
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2004 | BUILDING PRE-SLAB | RSUBA | Approved | IVRS - Inspection :* |
| 11/19/2004 | ELECTRIC - UNDERGROUND | RSUBA | Approved | IVRS - Inspection :* |
| 11/24/2004 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :*/WATER TEST WASTE & VENT UNDERGROUND ONLY OK . (3) SETS 4" RAIN DRAIN & OVERFLOW RAIN DRAINS SHOWN ON PLAN STUBBED UP 10' AND OUT OF BUILDING 12' WATER TEST OK. (PARTIAL APPROVAL) 1)NEED TO SEE PROPER WRAP ON PIPE PRIOR TO CONCRETE AND ADDITIONAL AIR OR WATER TEST WITON COMPLETED |
| 11/30/2004 | PLUMBING - PROGRESS | JSTANLEY | Approved | IVRS - Inspection :*/PARTIAL ON ROOF DRAINS IN SLAB ONLY. OK TO COVER. |
| 12/07/2004 | FRAMING | HLEYVA | Approved | IVRS - Inspection :* 1) CHECK ON DEMISING WLAL-SHEETROCK TO DECK |
| 12/08/2004 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* 1) OK WALLS ROOM # MEN AND WOMEN RESTROOMS, CORRIDOR AND LOUNGE |
| 12/08/2004 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/16/2004 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection :*/PROVIDE LETTER ON NEW LOCATION OF SHOCK ABSORBERS & TRAP PRIMERS NOT INSTALLED AS PER APPROVED PLAN |
| 12/30/2004 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection :*PARTIAL APPROVAL - OK @ LOUNGE AND BATHROOMS. |
| 01/21/2005 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | |
| 01/21/2005 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | |
| 01/21/2005 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection :* FINAL OK |
| 01/21/2005 | REINFORCED MASONRY PRE-GROUT | BSTEVENS | Approved | IVRS - Inspection :*APPROVED |
| 01/21/2005 | ELECTRIC - ABOVE CEILING | RSUBA | Approved | IVRS - Inspection :**APPROVED |
| 02/01/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* FIRE/SMOKE DAMPERS ARE NOT REQUIRED IN A NON-RATED WALL. PROVIDE A STAMPED LETTER FROM YOUR ENGINEER IF THE WALL IS NOT REQUIRED TO BE FIRE RATED. OK FOR TEMP C OF O. |
| 02/01/2005 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 02/03/2005 | ELECTRIC - UFER | RSUBA | Approved | |
| 02/03/2005 | ELECTRIC - CABLE DROP | RSUBA | Approved | |
| 02/03/2005 | ELECTRIC - TEMPORARY SERVICE | RSUBA | Approved | |
| 02/03/2005 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection :* |
| 02/03/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 02/04/2005 | MECHANICAL - FINAL | JMILITEL | Approved | |
| 02/04/2005 | MECHANICAL - PROGRESS | JMILITEL | Approved | |
| 02/04/2005 | BUILDING - FINAL | BSTEVENS | Approved | APPROVED |
| 02/04/2005 | BUILDING ABOVE CEILING | BSTEVENS | Approved | |
| 02/04/2005 | U VALUE FOR WINDOW | BSTEVENS | Approved | |
| 02/04/2005 | BUILDING - PROGRESS | BSTEVENS | Approved | |
| 02/07/2005 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
| 02/11/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 02/18/2005 | ENGINEERING - FINAL | NKALAHAR | Approved | APPROVED PER D ROBERTS |
| 02/22/2005 | PERMIT FINALED | BSTEVENS | Approved |