Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Address NEW:
81 E LAGUNA ST #01
Apply Date:
09/07/2004
Applicant:
NOLDEN CONSTRUCTION L L C ,
Description:
DUPLEX TD#16-01-78
Contractors:
  • NOLDEN CONSTRUCTION L L C ,

Permit Reviews

Permit Number - T04CM04039
Permit Status: Final
Permit Description: DUPLEX TD#16-01-78
Start Date Submittal Complete Date Status  
09/07/2004 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 09/07/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM04039
Permit Status: Final
Permit Description: DUPLEX TD#16-01-78
Total Outstanding Activity Conditions - 1
Date Name
09/07/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM04039
Permit Description: DUPLEX TD#16-01-78
Total Completed Inspections - 27
Date Description Inspector Results Comments
09/08/2004 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*/1) ABS DWV UNDERGROUND OK
WATER TEST ONE RISER TO TEN FEET
COPPER LOOPED OK
OK TO COVER
09/08/2004 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
09/17/2004 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :* APPROVED
09/20/2004 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
09/28/2004 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
10/11/2004 ROOF NAILING HLEYVA Approved IVRS - Inspection :*
10/11/2004 EXT METAL CLIPS/EXT SHEATHING HLEYVA Approved IVRS - Inspection :*
10/21/2004 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
10/21/2004 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
10/22/2004 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
10/25/2004 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*/PRESSURE TEST OK. BOND OK. PIPING OK. OK TO COVER.
11/01/2004 FRAMING AQUIROZ Approved IVRS - Inspection :*
11/03/2004 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
11/03/2004 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
11/16/2004 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection :*
12/22/2004 ELECTRIC - CABLE DROP MCAPISTR Approved IVRS - Inspection :*
12/22/2004 ELECTRIC - UNDERGROUND MCAPISTR Approved IVRS - Inspection :*
12/23/2004 TEP CLEARANCE - AM SLONG Approved CABLE DROP ONLY
03/11/2005 ELECTRIC - TEMPORARY SERVICE RMAJUTA Approved IVRS - Inspection :* APPROVED
03/22/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :* APPROVED
03/24/2005 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*1) YARDWATER INSPECTED UNDER SEPARATE PERMIT. 2) PLUMBING FINAL OK. OK FOR C OF O PENDING ANY OTHER INSPECTION.
03/24/2005 PLUMBING - YARD WTR LINE/TEST DSANTACR Approved IVRS - Inspection :*
04/04/2005 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :* 1) PLUMBING FINAL APPROVED ON 03/24/05 BY R MYERS
04/07/2005 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :* OK C OF O
04/20/2005 ENGINEERING - FINAL DROBERTS Approved
04/21/2005 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
04/22/2005 PERMIT FINALED JWEATHER Approved