Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
08/18/2004
Applicant:
RUMSEY, BRIAN FREDERICK
Description:
TI:REMODEL TO OPEN SPACE
Architects:
  • RUMSEY, BRIAN FREDERICK

Permit Reviews

Permit Number - T04CM03821
Permit Status: C of o
Permit Description: TI:REMODEL TO OPEN SPACE
Start Date Submittal Complete Date Status  
08/18/2004 PLANS OK TO SUBMIT - 3RD PARTY 08/20/2004 COMPLETED Review Details
08/20/2004 3RD PARTY REVIEW-COMMERCIAL TI 09/16/2004 COMPLETED Review Details
09/16/2004 POST 3RD PARTY REVIEW 09/21/2004 COMPLETED Review Details
11/04/2004 3RD PARTY REVIEW-REVISION/OTHER 12/14/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM03821
Permit Status: C of o
Permit Description: TI:REMODEL TO OPEN SPACE
Total Outstanding Activity Conditions - 1
Date Name
08/18/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM03821
Permit Description: TI:REMODEL TO OPEN SPACE
Total Completed Inspections - 23
Date Description Inspector Results Comments
10/12/2004 FRAMING RSUBA Approved IVRS - Inspection :*
10/12/2004 FIRE SPKLR - FINAL LTHOMAS Approved
10/12/2004 FIRE - FINAL LTHOMAS Approved
10/12/2004 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
10/14/2004 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
10/14/2004 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
10/14/2004 PLUMBING - FINAL IVR USER Approved IVRS - Ri canceled
10/15/2004 SHEET ROCK NAILING RSUBA Approved IVRS - Inspection :*
10/15/2004 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
11/09/2004 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
11/09/2004 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
11/09/2004 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
11/09/2004 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*/ 1) FRONT SIDE: FINISH BATHROOM
2) USE APPROVED STRAPS FOR M/C CABLE
3) FILL UNUSED OPENINGS IN BOXES
4) OK TO ROCK BATHROOM
11/09/2004 ELECTRIC - PROGRESS RHOLLAND Approved IVRS - Inspection :*
11/09/2004 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
12/17/2004 ENGINEERING - FINAL JBRUCKME Approved
12/17/2004 SIGN - FINAL JSONKIN Approved IVRS - Inspection :*
12/20/2004 RIGHT OF WAY - FINAL DLEE Approved
01/04/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :* APPROVED OK FOR FINAL
01/04/2005 BUILDING - PROGRESS BSTEVENS Approved IVRS - Inspection :*APPROVED
01/28/2005 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :* OK FINAL
02/02/2005 BUILDING - FINAL BSTEVENS Approved IVRS - Inspection :*APPROVED
02/03/2005 PERMIT FINALED TACHONG Approved